Prysmian and Draka Cable 14 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26380

Prysmian and Draka Cable 14 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26380

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 14 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26380
Prysmian and Draka Cable 14 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26380

Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor. 

Insultion: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. 

Shield: An aluminum/polyester tape with drain wire,100% coverage, is applied over each twisted pair and the cabled core. The single pair construction has only the overall shield and drain wire. 

Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option. 

Applications: 
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. 
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed). 
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). 
• This product may be manufactured in an unarmored or armored and sheathed version. 

Approvals: 
• IEEE 1580 and IEEE 45- Marine Shipboard Cable 
• UL 1309- Marine Shipboard Cable Type X110 
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110 
• CSA 22.2 No. 230- Type TC-ER 
• CSA 22.2 No. 230 & No. 38 Direct Burial (#14 AWG & larger) 
• Det Norske Veritas (DNV) 
• American Bureau of Shipping (ABS) 
• Transport Canada Approved AMS400-20-2 
• Transport Canada 8700-20-2 
• Lloyd’s Register of Shipping (LRS) 
• United States Coast Guard-46CFR 

Features/Ratings: 
• Superior resistance to oil, abrasion, moisture, sunlight, crush and impact 
• High strand count conductors provide superior flexibility 
• Higher allowable conductor operating temperature results in increased ampacity 
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3 
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A 
• Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6/1 kV 
• Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore 
• Meets the requirements of UL 1277 and UL 1569 for Type TC-ER exposed runs

technical specification:
number of pairs 4
insulation thickness (in) .030
insulation thickness (mm) 0.76
sheath thickness (in) 0.060
sheath thickness (mm)
1.5
cable diameter nominal (in) 0.730
cable diameter nominal (mm) 18.5
cable weight approximate (Lbs/Mft) 320
cable weight approximate (Kg/Km) 475
type designation
TP(I/S-0S)14PN-4
prysmian and draka cable Part number T26380