Prysmian and Draka Cable 16 AWG 12 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394056
Select gauge from drop-down menu for prices:
- Prysmian Low Voltage AIRGUARD™ Instrumentation IS/OS Cable 600V
- Prysmian and Draka Cable 16 AWG 1 Pair Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394051
- Prysmian and Draka Cable 16 AWG 1 Triad Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394052
- Prysmian and Draka Cable 16 AWG 2 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394053
- Prysmian and Draka Cable 16 AWG 4 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394054
- Prysmian and Draka Cable 16 AWG 4 Triads Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394059
- Prysmian and Draka Cable 16 AWG 8 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394055
- Prysmian and Draka Cable 16 AWG 12 Triads Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394060
- Prysmian and Draka Cable 16 AWG 24 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394057
- Prysmian and Draka Cable 16 AWG 36 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394058
Prysmian’s Low Voltage AIRGUARD™ Instrumenation Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric Airbag™ armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD™ provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, “No Knife/ No Saw” cable preparation, and substantially reduced cost of cable glands.
Conductor: Class B stranded bare, soft drawn copper circuit conductors
Insulation: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors.
Fillers: Flame resistant non-hygroscopic fillers (as needed)
Drain Wires: Class B stranded bare, soft drawn tinned copper drain wire.
Assembly: An aluminum/ polyester tape with drain wire,100% coverage, is applied over the twisted pairs or triads and the cabled core. Single pair or traid constructions have only the overall shield and drain wire.
Polymeric Armor/Enviromental Barrier: Foamed polymeric AIRBAG™ layer affords superior mechanical & environmental protection of the cable core
Outer Sheath: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic
Installation
• In Cable Tray Conduit
• Direct Buried Underground Duct
• Isolated in Air Wet Locations
• Dry Locations Industrial
• With Messenger
Specifications:
• ASTM B3 & ASTM B8 Class B Soft Drawn ConcentricLay Stranded Bare Copper Conductors
• ICEA S-82-552 (NEMA WC55) Instrumentation Cable Rating
• UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors Direct Buried Sunlight Resistant Oil Resistant
• iEEE 1202/FT-4 Flame Retardant
• UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating
• UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1 Hazardous Locations
• NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations
• CSA 22.2 No. 03 -40°C / -35°C Cold Bend/Cold Impact
Technical Specifications | |
Number and Circuit Conductor Size | 12/PR #16 AWG |
Insulation Thickness (Mils) | 30 |
Conductor Diameter (Inches) | 0.059 |
Nominal Overall Insulation OD (Inches) | 0.123 |
Nominal Overall Cable OD (Inches) | 1.275 |
Nominal Cable Weight (lbs/Mft) | 901 |
Minimum Bending Radius (Inches) | 15.3 |
Ampacity (Amps) (‡90°c) | 8.1 |
Gland, Explosion Proof, Class 1 Division 1,Barrier Type | 424BT06 |
Prysmian and Draka Cable Part Number | 394056 |