Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840058

Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840058

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840058
Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840058

Conductor: Tinned Standed circular copper, BS 6360, class 2

Insulation: EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding: Cores laid up in concentric layers

Inner covering: Flame retardant and halogen-free thermoset compound

Tape over inner covering: PET tape + rubberized Polyamide tape

Armour/screen: Galvanized steel wire braid

Tape over armour/screen: PET tape + rubberized Polyamide tape

Outer sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text: "meter mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour: Black

Core identification: All cores are offwhite with black numbers No 1,2,3.....

Operating temperature: 90°C

Operating Voltage: 0.6/1kV

Standards applied:
• BS6883 / UKOOA - Design
• BS6360 class 2 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 - Flame Retardant
• IEC60332-3-22 - Flame retardant
• IEC60754-1.2 - Halogen Free
• IEC 61034-1.2 - Low Smoke

Description:
• RFCU 0.6/1kV 2X 1.5mm2
• RFCU 0.6/1kV 2X 2.5mm2
• RFCU 0.6/1kV 2X 4mm2
• RFCU 0.6/1kV 2X 6mm2
• RFCU 0.6/1kV 2X 16mm2
• RFCU 0.6/1kV 2X 35mm2
• RFCU 0.6/1kV 3X 1.5mm2
• RFCU 0.6/1kV 3X 2.5mm2
• RFCU 0.6/1kV 3X 4mm2
• RFCU 0.6/1kV 3X 6mm2
• RFCU 0.6/1kV 3X 10mm2
• RFCU 0.6/1kV 3X 16mm2
• RFCU 0.6/1kV 3X 25mm2
• RFCU 0.6/1kV 3X 35mm2
• RFCU 0.6/1kV 3X 50mm2
• RFCU 0.6/1kV 3X 70mm2
• RFCU 0.6/1kV 3X 95mm2
• RFCU 0.6/1kV 4X 1.5mm2
• RFCU 0.6/1kV 4X 2.5mm2
• RFCU 0.6/1kV 4X 4mm2
• RFCU 0.6/1kV 4X 6mm2
• RFCU 0.6/1kV 4X 10mm2
• RFCU 0.6/1kV 4X 16mm2
• RFCU 0.6/1kV 4X 25mm2
• RFCU 0.6/1kV 4X 35mm2
• RFCU 0.6/1kV 4X 50mm2
• RFCU 0.6/1kV 4X 70mm2
• RFCU 0.6/1kV 4X 95mm2
• RFCU 0.6/1kV 5X 1.5mm2
• RFCU 0.6/1kV 7X 1.5mm2
• RFCU 0.6/1kV 7X 2.5mm2
• RFCU 0.6/1kV 12X 1.5mm2
• RFCU 0.6/1kV 12X 2.5mm2
• RFCU 0.6/1kV 19X 1.5mm2
• RFCU 0.6/1kV 19X 2.5mm2
• RFCU 0.6/1kV 27X 2.5mm2
• RFCU 0.6/1kV 37X 2.5mm2

Sheath Colour: BLACK

Design standard:
• BS 6883 : 1999
• BS 6883 : 1991

Application:
• Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

technical specification:
number of cores 3
cross section core, mm2 70
conductor diameter, mm 10.85
insulation thickness, mm 1.4
thickness inner sheath, mm 2
approx. diameter inner sheath, mm 34
diameter braid wire, mm 0.45
thickness outer sheath, mm 2.2
approx. overall diameter, mm 40
weight of cable approx. (kg/km) 3770
copper content approx. (kg/km) 1863
ukooa code wb370
prysmian and draka cable part number 840058