Description: Prysmian’s Low Voltage AIRGUARD™ Power Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric Airbag™ armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD™ provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, “No Knife/ No Saw” cable preparation, and substantially reduced cost of cable glands.

Conductor: Class B stranded bare, soft drawn coppercircuit conductors

Insulation: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors

Fillers: Extruded filler belt

Ground Wires: Class B stranded bare, soft drawn copper ground conductors (3)

Emi Shield:  Metallic tape provides 100% coverage

Polymeric Armor/Environmental Barrier: Foamed polymeric AIRBAG™ layer affords superior mechanical & environmental protection of the cable core

Outer Sheath: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic

Specifications
• ASTM B3 & ASTM B8 Class B Soft Drawn Concentric Lay Stranded Bare Copper Conductors
• ICEA S-82-558(NEMA WC70) Power Cable Rating
• UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors Direct Buried Sunlight Resistant Oil Resistant
• UL 1202/FT-4 Flame Retardant
• UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating
• UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1 Hazardous Locations
• NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations
• CSA 22.2 No. 03 -40oC/-35oC Cold Bend/ Cold Impact
• MSHA Mine Safety & Health Administration

Technical Specification
Number and Circuit Conductor Size 3/C #6 AWG 
Insulation Thickness Mils 45
Number of Grounding Conductor # 3
Ground Wires Size AWG 12 AWG
Conductor Diameter Inches 0.178
Nominal Overall Insulation (od) Inches 0.274
Nominal Overall Cable (od ) Inches 0.990
Nominal Cable Weight lbs/Mft 696
Minimum Bending Radius Inches 11.9
‡ Ampacity (amps) ‡90°c 75
Gland, Explosion Proof, Class 1 Division 1, Barrier Type 424BT04
Prysmian and Draka Cable Part Number 394046