Prysmian and Draka Cable RadHard 50 μm OM3 / OM4 Multimode Cable (MIL-PRF-49291/1)

Prysmian and Draka Cable RadHard 50 μm OM3 / OM4 Multimode Cable (MIL-PRF-49291/1)

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable RadHard 50 μm OM3 / OM4 Multimode Cable (MIL-PRF-49291/1)

Product Details

This DrakaEliteTM RadHard 50 μm core diameter OM3/OM4 multimode fibre (MMF) can be used for high irradiative environments (e.g. gamma rays, X-flash, neutrons protons) up to a dose of about 10 kGy. For extreme irradiative environments (some MGy dose) DrakaEliteTM Super RadHard 50 μm core diameter MMF is recommended. Note: 1 Gy = 100 Rad.

This Germanium-doped 50 μm core diameter OM3/OM4 RadHard MMF has been qualified and approved by the U.S. Defense Supply Center, Columbus (DSCC) in accordance with the U.S. Military MIL-PRF-49291/1 specification and offers increased laser-launch bandwidth (OM3 / OM4 quality).

Because Radiation Induced Attenuation (RIA) is a strong function of time after dose, dose rate, temperature, system operational wavelength, and system operational power, assessing the RIA performance of fibres should be conducted as close to conditions in the final application as possible.

The Draka 50 μm core diameter RadHard MMF can be used in all cable constructions, including loose tube, tight buffered, ribbon and central tube designs. This fibre complies with or exceeds IEC 60793-2-10 category A1a.2 and A1a.3 Optical Fibre Specification, TIA-492AAAC / 492AAAD and Telcordia GR-20-Core.

Prysmian Group’ fibre plant Draka Comteq Fibre B.V. in Eindhoven , Netherlands, is MIL-STD-790 certified.

Features:
• RadHard behaviour
• Coated with the dual layer UV Acrylate

Advantages:
• Suitable for medium irradiative environments
• Optimized performance in tight-buffer cable applications

steady state gamma irradiation test conditions – mil 49291-1
temperature dose rate total dose
- 28°c / 25°c / 85°c 0.50 gy/s (sio2) classified

irradiation test requirements – mil 49291-1
max. induced
attenuation @1310nm
attenuation at
specified recovery time
specified recovery time
< 50 db/km
(total dose classified)
< 15 @ -28 °c
< 5 @ 25 °c
< 5 @ 85 °c
1000 s