Prysmian Cable 750 MCM CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4F020A
Select gauge from drop-down menu for prices:
- Prysmian Cable 5kV TRXLPE Doubleseal 100% Copper Medium Voltage Utility Cables
- Prysmian Cable 2 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q43030A
- Prysmian Cable 2 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q44030A
- Prysmian Cable 1 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q45030A
- Prysmian Cable 1 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q46030A
- Prysmian Cable 1/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q48030A
- Prysmian Cable 1/0 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q47030A
- Prysmian Cable 2/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q49030A
- Prysmian Cable 3/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q4A030A
- Prysmian Cable 4/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Single Phase Full Neutral Medium Voltage Utility Cables Q4B030A
- Prysmian Cable 2 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q43020A
- Prysmian Cable 2 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q44020A
- Prysmian Cable 1 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q45020A
- Prysmian Cable 1 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q46020A
- Prysmian Cable 1/0 SOLID CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q47020A
- Prysmian Cable 1/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q48020A
- Prysmian Cable 2/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q49020A
- Prysmian Cable 3/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4A020A
- Prysmian Cable 4/0 AWG CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4B020A
- Prysmian Cable 250 MCM CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4C020A
- Prysmian Cable 350 MCM CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4D020A
- Prysmian Cable 500 MCM CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4E020A
- Prysmian Cable 1000 MCM CU 5kV TRXLPE DOUBLESEAL 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables Q4G020A
Conductors: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.
Conductor shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.
Insulation: Natural high dielectric VOLTALENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, assuring resistance to treeing.
Insulation shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Matallic shield: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration.
Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.
Applications:
Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.
Specifications and ratings:
•AEIC- AEIC CS8
•ICEA- ICEA S-94-649
•ICEA- ICEA T-31-610
•ICEA- ICEA T-34-664
For 90°C continuous, 130°C emergency, 250°C short-circuit operation
Options:
•Black LLDPE jacket with no stripes
• Multiplex cables
•Super smooth conductor shield
•Tinned round and flat strap neutrals
• Compact stranded conductors
•UL MV-90 rating if required
•46kV
•RUS Bulletin 1728F
•U1 where applicable
technical specification: | |
conductor | 750 mcm cu |
insulation thickness (mils) | 90 |
concentric neutral | 20-#9 |
conductor diameter (in) - (a) | 0.974 |
insulation diameter (in) - (b) | 1.22 |
insulation shield diameter (in) - (c) | 1.30 |
jacket diameter (in) - (d) | 1.70 |
cable weight (lbs/kft) | 3774 |
minimum bending radius (in) | 14 |
ampacity (amps) - (90°c in duct) | 540 |
+/- sequence impedance resistance (mw/ft) - (90°c in duct) | 26 |
+/- sequence impedance reactance (mw/ft) - (90°c in duct)
|
35 |
zero sequence impedance resistance (mw/ft)†† - (90°c in duct)
|
72 |
zero sequence impedance reactance (mw/ft)†† - (90°c in duct)
|
14 |
† ampacity (amps) - (90°c direct buried) | 552 |
+/- sequence impedance resistance (mw/ft) - (90°c direct buried)
|
48 |
+/- sequence impedance reactance (mw/ft) - (90°c direct buried)
|
40 |
zero sequence impedance resistance (mw/ft)†† - (90°c direct buried)
|
71 |
zero sequence impedance reactance (mw/ft)†† - (90°c direct buried)
|
14 |
prysmian cable part number | Q4F020A |