RSCC Aerodefense 21 AWG 3 Pairs Armored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-09AN
Select gauge from drop-down menu for prices:
- RSCC Aerodefense MIL-DTL-24643/21 and 24 Low Smoke Thermocouple Wire Cable
- RSCC Aerodefense 14 AWG 4 Pairs Unarmored Iron and Constantan Thermocouple Wire Cable MIL-DTL-24643/21-01UN
- RSCC Aerodefense 14 AWG 4 Pairs Armored Iron and Constantan Thermocouple Wire Cable MIL-DTL-24643/21-03AN
- RSCC Aerodefense 14 AWG 4 Pairs Unarmored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/21-02UN
- RSCC Aerodefense 14 AWG 4 Pairs Armored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/21-04AN
- RSCC Aerodefense 16 AWG 3 Pairs Armored Iron and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-01AN
- RSCC Aerodefense 16 AWG 7 Pairs Armored Iron and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-02AN
- RSCC Aerodefense 16 AWG 12 Pairs Armored Iron and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-03AN
- RSCC Aerodefense 16 AWG 1 Pair Armored Chromel and Alumel Thermocouple Wire Cable MIL-DTL-24643/24-04AN
- RSCC Aerodefense 16 AWG 3 Pairs Armored Chromel and Alumel Thermocouple Wire Cable MIL-DTL-24643/24-05AN
- RSCC Aerodefense 16 AWG 7 Pairs Armored Chromel and Alumel Thermocouple Wire Cable MIL-DTL-24643/24-06AN
- RSCC Aerodefense 16 AWG 12 Pairs Armored Chromel and Alumel Thermocouple Wire Cable MIL-DTL-24643/24-07AN
- RSCC Aerodefense 21 AWG 1 Pair Armored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-08AN
- RSCC Aerodefense 21 AWG 7 Pairs Armored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-10AN
- RSCC Aerodefense 21 AWG 12 Pairs Armored Copper and Constantan Thermocouple Wire Cable MIL-DTL-24643/24-12AN
Conductor: As listed in the table below
Insulation: Watertight Silicone and Glass Braids
Jacket: Irradiation Cross-Linked Low Smoke Polyolefin (/21); Low Smoke Red Silicone Rubber (/24)
Applications:
MIL-DTL-24643 Slant Sheets 21 and 24 utilize insulated conductors manufatured with a combination of silicone and glass braids which provide circuit integrity in case of a catastrophic fire. They are used for thermocouple or pyrometer applications. These constructions are watertight. The overall jacket is an irradiation cross-linked low smoke polyolefin for Slant Sheet 21 and a low smoke, red silicone rubber for Slant Sheet 24. The silicone rubber jacketed cables are armored with an aluminim braid to provide mechanical protection.
technical specification: | |
conductor(awg) | 21 |
conductor(stranding) | 7 |
cable type | LSTCTX |
size | 3 |
slant sheet | 24 |
armor | Y |
product description | Copper & Constantan Thermocouple, silicone jacket, 3 pairs. |
rscc aerodefense military part number | MIL-DTL-24643/24-09AN |