Seacoast 14 AWG 10 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
Select gauge from drop-down menu for prices:
Seacoast 14 AWG 10 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG Multi-Conductors Type C14XT, C14XTA, C14XTB and C14(OS)XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 7 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 10 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 14 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 20 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 24 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 30 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 37 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 44 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 61 Conductors Type C14XT 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 7 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 14 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 20 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 24 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 30 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 37 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 44 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
- Seacoast 14 AWG 61 Conductors Type C14(OS)XT Overall Shield 600 Volts XLP Insulation Cable
Multi-conductors (7 through 61), 600 Volts, 90°C rated, stranded bare copper, Cross-Linked Polyethylene (XLP)
insulation, color coded in accordance with IEEE Std. 45, fillers where necessary, binder tape as required, PVC
jacket, braided metal armor (optional). Flame retardant – meets IEEE 1202/UL 1685 flame test requirements.
Type C14(OS)XT variant includes an overall shield of polyester/aluminum foil tape with drain wire under the
jacket.
Type C14XTA with aluminum armor, Type C14XTB with bronze armor.
technical specification: | |
awg | 14 |
cable type awg #14 | C14(OS)XT-10 |
number of conductors | 10 |
* stranding class b or c | 7/19 |
circular mills | 4107 |
nom. cross section area (mm2) | 2.08 |
cable ** nominal o.d. (inches) | 0.675 |
approximate weight lbs/1000 feet (unarmored) | 261 |
approximate weight lbs/1000 feet (aluminum) | 380 |
ampacity @ 45°c Ambient (90° c rating) | 12 |