Service Wire 2/0 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP2/03
Select gauge from drop-down menu for prices:
- Service Wire Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable
- Service Wire 14 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP14/3
- Service Wire 12 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP12/3
- Service Wire 10 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP10/3
- Service Wire 8 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP8/3
- Service Wire 6 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP6/3
- Service Wire 4 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP4/3
- Service Wire 3 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP3/3
- Service Wire 2 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP2/3
- Service Wire 1 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP1/3
- Service Wire 1/0 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP1/03
- Service Wire 3/0 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP3/03
- Service Wire 4/0 AWG Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP4/03
- Service Wire 250 MCM Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP250/3
- Service Wire 350 MCM Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP350/3
- Service Wire 500 MCM Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP500/3
- Service Wire 600 MCM Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP600/3
- Service Wire 750 MCM Jacketed MC Service Drive ASD/VFD XHHW-2 600 Volt Copper Cable ASDGAP750/3
Description:
3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield and galvanized steel interlocked armor with overall PVC jacket. Jacket available in colors.
Application:
For use in ASD/VFD applications.
Suitable for use in hazardous locations:
• Class I - Div 2
• Class II - Div 2
• Class III - Div 1 and 2
Standards:
• UL 1569
• ICEA S-95-658/NEMA WC-70
Flame Rated:
• IEEE 383 (70,000 BTU)
• ICEA T-29-520 (210,000 BTU)
• IEEE 1202/CSA FT-4
• Two-hour Firewall
• Temperature Rated at 90°C Wet/Dry Sunlight and Oil Resistant II Jacket Direct Burial
• Color Code: Method 4
• RoHS Compliant
technical specification: | |
size awg or kcmil | 2/0 |
strand(no.) | 19 |
insulation thickness(mils) | 55 |
grounding conductors(awg) | 3-#6 |
diameter over armor(inch) | 1.41 |
pvc jacket thickness(mils) | 50 |
approx. diameter overall(inch) | 1.51 |
approx. net weight(lb/1000') | 2,436 |
ampacity*(30°c ambient) 90°c wet/dry | 195 |
service wire part number | ASDGAP2/03 |