Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 4 Cond.
Select gauge from drop-down menu for prices:
Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 4 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14-16 AWG
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 2 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 3 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 4 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 5 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 6 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 7 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 8 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 9 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 10 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 12 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 15 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 18 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 20 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 25 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 16 AWG (19x.0117") Tinned Copper - 30 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 2 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 3 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 5 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 6 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 7 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 8 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 9 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 10 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 12 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 15 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 20 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 25 Cond.
- Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 30 Cond.
Plenum : Multi-Conductor (UL) CL2P / CMP Shielded - 14 AWG (19x.0150") Tinned Copper - 4 Cond.
Technical Specifications: | |
Aero P/N | 1420 |
AWG | 14 |
No. of Cond. | 4 |
Insulation Thickness (inches) | .006 |
Jacket Thickness (inches) | .010 |
Jacket O.D. (inches) | .214 |
Lbs/1000' | 68 |
Specifications:
- Plenum : Multi-Conductor (UL)
- CL2P / CMP Shielded
- Plenum: [16 & 14 AWG ]
- Compliance: (UL) c(UL) CL2P or CMP
- 200°C, E-CTFE 150°C and LS PVC 60°C
Conductor:
Stranded T.C.
Insulation:
FEP
Color Code:
Chart 1
Shield:
Aluminum/Mylar
Jackets Available:
- FEP (200°C)
- E-CTFE (150°C) Add "K" to P/N
- Plenum LS PVC PVC Jacket available
Industry Approvals:
- NEC Article 725-CL2P or
- NEC Article 800-CMP
- C(UL) (CMP only)
Impedance: (FEP only)
- (AWG 16) 35 Ohms Nom.
- (AWG 14) 30 Ohms Nom.
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
- (AWG 16) 42 pF/ft Nom.
- (AWG 14) 47 pF/ft Nom.
Temperature Rating:
- -80°C to +200°C (FEP/FEP)
- -40°C to +150°C (FEP/E-CTFE)
- -5°C to +75°C (FEP/LS PVC)
Put Ups:
- 1000 Feet (+- 10%)