Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 2/0
Select gauge from drop-down menu for prices:
Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 2/0
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 4
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 3
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 2
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 1
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 1/0
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 3/0
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 4/0
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 250
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 300
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 350
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 400
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 500
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 600
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 750
- Teck 90 Armoured Power Single Conductor 1000V XLPE/PVC/AIA/PVC - AWG Size Cond. 1000
Technical Specifications: | |
Catalog Number | 05019-05-010 |
AWG Size Cond. | 2/0 |
AWG Bond Wire |
4 |
Insulation Thickness (in.) | 0.080 |
Approximate Diameter (Over) Insul. (in.) | 0.580 |
Approximate Diameter (Over) Inner Jacket (in.) | 0.710 |
Approximate Diameter (Over) Armour (in.) | 0.950 |
Approximate Diameter (Over) Outer Jacket (in.) | 1.040 |
Copper Content LB/MFT | 544 |
Copper Content KG/KM | 810 |
Net Weight w/ Armour LB/MFT |
860 |
Net Weight w/ Armour KG/ KM | 1280 |
Amp. (30°C Ambient) | 300 |
Specifications:
- Teck 90 Armoured Power
- Single Conductor 1000V
- XLPE/PVC/AIA/PVC
- CSA FT1 & FT4
- CSA C22.2 No. 131 & 174
- IEEE 383 & 1202 (70,000 BTU/hr) Flame Test
- ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test
CONSTRUCTION:
- Conductor: Bare copper Class B compact or compressed stranded
- Insulation: Cross-Linked Polyethylene (XLPE) Type RW90
- Ground (Bonding) Conductor: Concentric serving of solid bare copper wires applied over the insulation
- Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
- Armour: Aluminum Interlocked Armour (AIA)
- Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
- Options: Other coloured outer jacket and constructions available upon request