General Cable Telecommunication Filled Solid® Cable 24/300 AWG RDUP RUS PE-39 AL
Select gauge from drop-down menu for prices:
- General Cable Telecommunication Filled Solid® Cable RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 19/6 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 19/12 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 19/25 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 22/6 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 22/12 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 22/25 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 22/50 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 22/100 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/6 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/12 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/25 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/50 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/100 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/200 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/400 AWG RDUP RUS PE-39 AL
- General Cable Telecommunication Filled Solid® Cable 24/600 AWG RDUP RUS PE-39 AL
Product Details
Conductors: Solid, annealed copper; sizes 19, 22 and 24 AWG
Insulation: Solid, high density polyethylene, color- coded in accordance with telephone industry standards
Twisted Pairs: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk
Core Assembly:
• 25 pairs and less: pairs are assembled together in a single group
• More than 25 pairs: pairs are arranged in groups, each group having a color-coded unit binder
Filling Compound: The entire core assembly is completely filled with ETPR compound, filling the interstices between the pairs and under the core tape
Core Wrap: Non-hygroscopic dielectric tape applied longitudinally with an overlap
Sheath:
Aluminum Shield:
• Corrugated, copolymer coated, 0.008" aluminum tape applied longitudinally with an overlap
• The sheath interfaces are flooded with an adhesive water-blocking compound
Jacket: Black, linear low density polyethylene
Application(s): Intended for duct and direct buried installations where protection against water and moisture entry is required and may also be installed aerially
Compliances:
• Rural Development Utility Program (RDUP) 7 CFR 1755.390 (RUS PE-39)
• RoHS Compliant (effective 1/1/10)
• ANSI/ICEA S-84-608-2007
Packaging:
• Standard lengths are shipped on non-returnable wood reels
• Non-standard packaging is available upon request
technical specification | |
awg | 24 |
pairs | 300 |
o.d. (inches) | 1.60 |
weight (lbs/mft) | 1380 |
standard length (ft) | 2500 |
catalog number | 7524705 |