General Cable VERTITECK® 350MCM TECK90 3C XLPE PVC GSIA PVC Power Unshielded Armored 1kV CSA

General Cable VERTITECK® 350MCM TECK90 3C XLPE PVC GSIA PVC Power Unshielded Armored 1kV CSA

VERTITECK 350MCM TECK90 3C XLPE PVC GSIA PVC Power Unshielded Armored 1kV CSA

Conductor: 1/0 AWG thru 1000 kcmil bare copper compact Class B strand

Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: printed numbers

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Galvanized Steel Interlocked Armor (GSIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp, or wet locations • For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands
• Cost-effective alternative to installation n conduit
• Typical vertical installations include mine shafts, tall commercial buildings, inclined tunnels and vertical cable trays
(Note that the overall jacket is required for all damp and wet locations and for all corrosive environments: CE Code Part 1, Rules 12-708 and 22-200)

Features:
• Rated at 90?C wet or dry
• The jacket under the armor (inner jacket) is designed with longitudinal raised ribs. The armor is then applied and bites into these ribs to provide a solidly locked construction. This feature enables the cable to be self-supporting (core will not slip) during vertical installation when cable weight is supported by the copper conductors
• Lighter than mine shaft cable with conventional steel wire armor (SWA)
• More flexible than SWA cables, resulting in easier handling during installation
• Terminations and connections to electrical cabinets are similar to standard TECK90 cables
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances: CSA Standard C22.2 No. 131 and No. 174

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specifications:
cond. size (awg/kcmil) 350
no. of cond 3
ground wire size (awg) 3
min. avg insulation thickness(inches) 0.090
min. avg insulation thickness(mm) 2.29
nominal diameter (over)(insulation in inches) 0.81
nominal diameter (over)(insulation in mm) 20.4
nominal diameter (over)(armor in inches) 2.36
nominal diameter (over)(armor in mm) 60.0
nominal diameter (over)(cable in inches) 2.50
nominal diameter (over)(cable in mm) 63.5
copper weight(lbs/1000 ft) 2475
copper weight(kg/km) 5171
net weight w/steel armor(lbs/1000 ft) 6100
net weight w/steel armor(kg/km) 9080
ampacity** (30?c ambient) 350
maximum self-supporting length***(m) 288
catalog number 11289.416200*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question