SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Red

SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Red


Technical Specifications:
Part Number 180161
AWG 12
No. of Conductors
2
Jacket Color Red
Ins. Walls (Mils) 60
Jacket Walls (Mils) 45
O.D. .300"x.505"
Weight Lbs/M 105

Specifications:

  • SPECIAL DIRECT BURIAL
  • IRRIGATION CONTROL CABLE
  • INSULATION: POLYVINYL CHLORIDE
  • JACKET: IMPREGNATED POLYETHYLENE
  • SIZES: 14-12 AWG, 2 CONDUCTOR

Scope:
This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.

Conductor:
Soft annealed tin coated solid copper conforming to ASTM B-33.

Insulation:
Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF/TWU rated 75°C.

Color Coding:
Black, Red

Cable Assembly:
Insulated conductors are laid parallel.

Outer Jacket:
Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3/64" minimum jacket material to completely fill interstices between the two insulated conductors.

Jacket Color:
Several

Color Coding:
Black, Red

Surface Print:
"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI/2-WIRE SYSTEMS" RoHS. Maxi is a trademarks of Rain Bird Corporation.

SPLICING RECOMMENDATIONS:
Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR/Y-6, as manufactured by the 3M Company (Paige specification P7364D)

Put-Ups:
2500' reels and odd lengths.

Additional Notes:
The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this "irrigation cable" as "building wire." The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied/operating voltage is well below the 48V rating.