TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 12 AWG 2 COND - Black
Select gauge from drop-down menu for prices:
- Toro Jacketed Decoder Cables Direct Burial - Solid Copper, 2-Conductor
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Red
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Black
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Yellow
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Green
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Blue
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Gray
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Orange
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Purple
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 14 AWG 2 COND - Tan
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 12 AWG 2 COND - Red
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 12 AWG 2 COND - Yellow
- TORO JACKETED DECODER CABLES DIRECT BURIAL - SOLID COPPER, 2-CONDUCTOR - 12 AWG 2 COND - Green
Technical Specifications: | |
Part NumberY | 170804BLK |
Size | 12 AWG 2 COND. |
Jacket Color |
Black |
SHIPPING WEIGHT (Pounds/1000') | 95 |
Specifications:
- TORO JACKETED DECODER CABLES DIRECT BURIAL
- SIZES: 14 & 12 AWG
- SOLID COPPER, 2-CONDUCTOR
Scope:
AThis specification covers jacketed
cables containing two listed Sprinkler
Systems Wires, single conductor,
suitable for direct burial, for operation
up to 600 volts, and temperatures
up to 60°C
Inner Conductors:
Soft drawn bare copper meeting the
requirements of ASTM specification
B-3 or B-8. Insulation shall be low
density high molecular weight polyethylene
and a thickness of 0.045”,
per Paige Electric specification
P7079D. The two conductors (black
and white) shall be twisted with a
minimum lay of 4”.
Overall jacket: :
High density polyethylene with a
thickness of 0.035”. Available with
different color jackets as listed in
the table below. The jacket shall
be sufficiently round, and loose, to
facilitate its removal when being
stripped. Minimum inner diameters
of the outer jacket:
Construction:
- 14 AWG/2c - 0.358 (inches), 9.1 (mm)
- 12 AWG/2c - 0.386 (inches), 9.8 (mm)
A “T” drill bit, whose diameter is
0.358”, shall be used to measure
the minimum inner diameter of 14
AWG/2c cables.
A “W” drill bit, whose diameter is
0.386”, shall be used to measure
the minimum inner diameter of 12
AWG/2c cables.
Surface Print:
2.31 Inner Conductors –
“Paige Electric P7079D
14 or 12 AWG PE Listing file
Number 600V Sprinkler System
Wire Direct Burial”
2.32 Outer Jacket – “Paige Electric,
P7350D, 14 or 12 AWG PE
600V Sprinkler System
Wire Direct Burial Only for Toro
Decoder Systems RoHS”
TEMPERATURE RATING:
-55ºC to +60ºC
PUT-UPS:
500' (164m), 1000' (328m), 2500' (762m)
and some odd lengths.
SPLICING RECOMMENDATIONS:
Wire splices are the weak link of any electrical
circuit. It is especially important to make
proper joints in irrigation systems because
the joints are exposed to wet and damp
environments that can cause corrosion of the
copper conductor, and premature failure.
Paige Electric recommends the strict use of
Model DBR/Y-6, as manufactured by the 3M
Company (Paige specification P7364D)
Specification Data:
- ASTM B-398 Aluminum Alloy 6201-T81 wire for electrical purposes
- ASTM B-399 Concentric-lay-stranded 6201-T81 Aluminum Alloy conductors