General Cable ACWU90® 3C 3/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
Select gauge from drop-down menu for prices:
- General Cable ACWU90® 3C XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 6 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 4 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 2 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 1 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 1/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 2/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 4/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 250MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 350MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 500MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 600MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 750MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
Conductor: 6 AWG thru 750 kcmil bare ACM aluminum (8000 series aluminum) compact Class B strand
Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 6 AWG to 2 AWG—black, white and red; 1/0 AWG to 750 kcmil—per ICEA Method 4, individual conductors colored black with conductor number surface printed in contrasting ink
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare aluminum (ACM) conductor
Armor: Aluminum Interlocked Armor (AIA)
Jacket: ACID-FLAME-CHECK ??® flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands
• For service entrance installations
Features:
• Rated at 90°C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40°C
Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 51 and No. 174
• CSA Approval File Number 157657
Flame Test Compliances: CSA FT1 and FT4
Other Compliances:
• Hazardous Location Rating: HL
• OSHA Acceptable
Packaging: For Canadian customers, nominal standard lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for cut to length, lagging and pulling eyes
technical specifications: | |
cond. size (awg/kcmil) | 3/0 |
cond. strand | 16/.115 |
nominal conductor o.d.(inches) | 0.421 |
nominal conductor o.d.(mm) | 10.693 |
min. avg. insulation thickness(inches) | 0.050 |
min. avg. insulation thickness(mm) | 1.270 |
nominal diameter (over)(insulation in inches) | 0.520 |
nominal diameter (over)(insulation in mm) | 13.208 |
nominal diameter (over)(armor in inches) | 1.510 |
nominal diameter (over)(armor in mm) | 38.354 |
nominal diameter (over)(cable in inches) | 1.630 |
nominal diameter (over)(cable in mm) | 41.402 |
aluminum weight*(lbs/1000 ft) | 513 |
aluminum weight*(kg/km) | 746 |
net weight( lbs/1000 ft)
|
1001 |
net weight(kg/km) | 1457 |
90?c ampacity** (30°c ambient) | 175 |
catalog number | 11281.035300 |