Belden 88444 Cable 22 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Plenum FEP Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable 22 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable
- Belden 8795 Cable 22 AWG 2 Conductors Audio Control and Instrumentation Multi Conductor Solid BC UnShielded Non Plenum Cable
- Belden 8794 Cable 22 AWG 3 Conductors Audio Control and Instrumentation Multi Conductor Solid BC UnShielded Non Plenum Cable
- Belden 9794 Cable 22 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Solid BC UnShielded Non Plenum Cable
- Belden 1242A Cable 22 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Solid BC UnShielded Non Plenum PVC Jacket Cable
- Belden 8442 Cable 22 AWG 2 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8443 Cable 22 AWG 3 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8444 Cable 22 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8445 Cable 22 AWG 5 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9430 Cable 22 AWG 7 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9421 Cable 22 AWG 8 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9423 Cable 22 AWG 9 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8456 Cable 22 AWG 10 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8457 Cable 22 AWG 12 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8458 Cable 22 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9431 Cable 22 AWG 20 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 8459 Cable 22 AWG 25 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9432 Cable 22 AWG 30 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9433 Cable 22 AWG 40 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 9434 Cable 22 AWG 50 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable
- Belden 88442 Cable 22 AWG 1 Pair Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Plenum FEP Jacket Cable
- Belden 82442 Cable 22 AWG 1 Pairs Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC Plenum Flamarrest Jacket Cable
- Belden 82444 Cable 22 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC Plenum Flamarrest Jacket Cable
Description:
• 22 AWG stranded (7x30) TC conductors, conductors cabled, FEP insulation, FEP jacket.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.178
Outer Jacket:
• Material: FEP - Fluorinated Ethylene Propylene
• Nom. Wall Thickness (mm): 0.254
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -70°C To +200°C
• Bulk Cable Weight: 20.835 Kg/Km
• Max. Recommended Pulling Tension: 160.135 N
• Min. Bend Radius/Minor Axis: 31.750 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.49215
• Nom. Capacitance Conductor to Conductor (pF/m): 59.058
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 49.215
• Nominal Conductor Loop Resistance @ 20°C (Ohm/km): 98.43
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.3 Amps/Conductor @ 25°C (10°C rise in temp)
Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6
Suitability:
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 8444
technical specification: | |
awg | 22 |
# conductors | 4 |
stranding | 7x30 |
no. of conductors | 4 |
conductor material | tinned copper |
dia. (mm) | - |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 3.073 |
belden cable part number | 88444 |