Belden 9434 Cable 22 AWG 50 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Belden 9434 Cable 22 AWG 50 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Select gauge from drop-down menu for prices:

Belden 9434 Cable 22 AWG 50 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Precio habitual $30.36 $20.24 Oferta /per Foot

Belden 9434 Cable 22 AWG 50 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Description:
• 22 AWG stranded (7x30) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.279

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.143

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2576)
• Bulk Cable Weight: 278.293 Kg/Km
• Max. Recommended Pulling Tension: 1966.104 N
• Min. Bend Radius/Minor Axis: 127 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2576 (150 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.55777
• Nom. Capacitance Conductor to Conductor (pF/m): 111.554
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 51.1836
• Max. Operating Voltage - UL: 300 V RMS (CMG)
• Max. Operating Voltage - UL: 150 V RMS (UL AWM Style 2576)
• Max. Recommended Current: 1.2 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# conductors 50
stranding 7x30
no. of conductors 50
conductor material tinned copper
dia. (mm) -
outer shield - material unshielded
overall cable- nominal dia. (mm) 12.700
belden cable part number 9434

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.