Belden 9578 Cable 18 AWG 4 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Fire Alarm Power Limited Fire Protective Signaling Circuit Multi Conductor Cable
- Belden 9576 Cable 22 AWG 6 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9571 Cable 18 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9574 Cable 18 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9572 Cable 16 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9575 Cable 16 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9579 Cable 16 AWG 4 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9580 Cable 14 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9581 Cable 14 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9582 Cable 12 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9583 Cable 12 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
Description:
• 18 AWG solid bare copper conductors, conductors cabled, PVC insulation, overall Beldfoil® shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.4318
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 71.434 Kg/Km
• Max. Recommended Pulling Tension: 440.372 N
• Min. Bend Radius/Minor Axis: 69.850 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, FPLR
• NEC Articles: 760
• CEC/C(UL) Specification: FAS105
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: California State Fire Marshall
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.554489
• Nom. Capacitance Conductor to Conductor (pF/m): 141.083
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 259.855
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 20.9984
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 38.3877
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.2 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# conductors | 4 |
stranding | solid |
no. of conductors | 4 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 6.680 |
belden cable part number | 9578 |