Belden 9685 22 AWG 1 Pair Combination Shields Special Audio Communication and Instrumentation Paired Cable
Select gauge from drop-down menu for prices:
- Belden Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 8434 25 AWG 2 Pairs Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 8730 22 AWG 2 Pairs Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 8724 22 AWG 2 Pairs Combination Shields Special Audio Communication and Instrumentation PVC Jacket Cable
- Belden 8728 22 AWG 2 Pairs Combination Shields Special Audio Communication and Instrumentation PP Insulation Cable
- Belden 8763 20 AWG 1 Pair Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 8722 20 AWG 2 Pairs Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 8725 20 AWG 4 Pairs Combination Shields Special Audio Communication and Instrumentation Paired Cable
- Belden 9155 20 and 18 AWG Combination Shields Special Audio Communication and Instrumentation Paired Cable
Description:
• 22 AWG stranded (7x30) tinned copper conductors, PVC insulation, one pair Beldfoil® shielded (100% coverage), stranded tinned copper drain wire, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.356
Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 22
• Stranding: Stranded
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 90°C
• Bulk Cable Weight: 34.229 Kg/Km
• Max. Recommended Pulling Tension: 121.436 N
• Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• NEC Articles: 800
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.3281
• Nom. Capacitance Conductor to Conductor (pF/m): 196.86
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 324.819
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 55.777
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.3 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 22 |
# pairs | 1 |
stranding | 7x30 |
no. of conductors | 3 |
conductor material | tinned copper |
outer shield - type | - |
outer shield - material | - |
overall cable- nominal dia. (mm) | 5.055 |
belden cable part number | 9685 |