Eutex Cable 32 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32T.75-Y
Select gauge from drop-down menu for prices:
Eutex Cable 32 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32T.75-Y
- Eutex Cable RFOU (i) S1/S5 Instrumentation 250 V Flame Retardant Individual Screen Cable
- Eutex Cable 1 Pair 2 Conductor 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01P.75-Y
- Eutex Cable 2 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02P.75-Y
- Eutex Cable 4 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04P.75-Y
- Eutex Cable 7 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07P.75-Y
- Eutex Cable 8 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08P.75-Y
- Eutex Cable 12 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12P.75-Y
- Eutex Cable 16 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16P.75-Y
- Eutex Cable 19 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19P.75-Y
- Eutex Cable 24 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24P.75-Y
- Eutex Cable 32 Pairs 2 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32P.75-Y
- Eutex Cable 1 Pair 3 Conductor 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01P.75-Y
- Eutex Cable 2 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02T.75-Y
- Eutex Cable 4 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04T.75-Y
- Eutex Cable 7 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07T.75-Y
- Eutex Cable 8 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08T.75-Y
- Eutex Cable 12 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12T.75-Y
- Eutex Cable 16 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16T.75-Y
- Eutex Cable 19 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19T.75-Y
- Eutex Cable 24 Pairs 3 Conductors 0.75 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24T.75-Y
- Eutex Cable 1 Pair 2 Conductor 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01P001-Y
- Eutex Cable 2 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02P001-Y
- Eutex Cable 4 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04P001-Y
- Eutex Cable 7 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07P001-Y
- Eutex Cable 8 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08P001-Y
- Eutex Cable 12 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12P001-Y
- Eutex Cable 16 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16P001-Y
- Eutex Cable 19 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19P001-Y
- Eutex Cable 24 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24P001-Y
- Eutex Cable 32 Pairs 2 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32P001-Y
- Eutex Cable 1 Pair 3 Conductor 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01T001-Y
- Eutex Cable 2 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02T001-Y
- Eutex Cable 4 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04T001-Y
- Eutex Cable 7 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07T001-Y
- Eutex Cable 8 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08T001-Y
- Eutex Cable 12 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12T001-Y
- Eutex Cable 16 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16T001-Y
- Eutex Cable 19 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19T001-Y
- Eutex Cable 24 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24T001-Y
- Eutex Cable 32 Pairs 3 Conductors 1 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32T001-Y
- Eutex Cable 1 Pair 2 Conductor 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01P1.5-Y
- Eutex Cable 2 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02P1.5-Y
- Eutex Cable 4 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04P1.5-Y
- Eutex Cable 7 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07P1.5-Y
- Eutex Cable 8 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08P1.5-Y
- Eutex Cable 12 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12P1.5-Y
- Eutex Cable 16 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16P1.5-Y
- Eutex Cable 19 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19P1.5-Y
- Eutex Cable 24 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24P1.5-Y
- Eutex Cable 32 Pairs 2 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32P1.5-Y
- Eutex Cable 1 Pair 3 Conductor 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-01T1.5-Y
- Eutex Cable 2 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-02T1.5-Y
- Eutex Cable 4 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-04T1.5-Y
- Eutex Cable 7 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-07T1.5-Y
- Eutex Cable 8 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-08T1.5-Y
- Eutex Cable 12 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-12T1.5-Y
- Eutex Cable 16 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-16T1.5-Y
- Eutex Cable 19 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-19T1.5-Y
- Eutex Cable 24 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-24T1.5-Y
- Eutex Cable 32 Pairs 3 Conductors 1.5 Nominal Area RFOU (i) S1/S5 Instrumentation 250V Flame Retardant Cable EUT-01C-32T1.5-Y
Conductor: Tinned stranded compacted copper IEC 60228 class 2
Insulation: Halogen free EPR compound
Individual Screen: Copper/polyester tape Tinned copper train wire
Bedding: Halogen free compound
Armour: Tinned copper wire braid according to IEC 60092-376:2003
Outer Sheath: SHF2 MUD thermoset compound Halogen free & MUD resistant
Pair/Triple Identification
• Pair: Black Light Blue
• Triple: Light Blue Black Brown (Pairs/triples progressively numbered)
• Sheath color: Grey (Blue for intrinsically safe)
Sheath Marking:
• RFOU(i) S1/S5 250 V n x p(trp) x s mm²
• NEK 606:2004 IEC 60332-3-22 QA ref Metric marking
technical specification: | |
construction (mm²) | 32x3x0.75 |
insulation thickness (mm)
|
0.6 |
under armor diameter (mm) | 38.2 |
outer sheath thickness (mm)
|
2.6 |
overall diameter (approx) (mm) | 46.0 |
weight (approx) (kg/km) | 3170 |
bending radius (mm) | 280 |
conductor resistance at 20°c (ω/km) | 27.6 |
Eutex cable part number | EUT-01C-32T.75-Y |
Application Standard : | |
design and construction | iec 60092-376:2003 |
nominal voltage uo/u | 250 v |
operating temperature | 90°c |
flame retardancy | iec 60332-1, iec 60332-3-22 |
corrosivity | iec 60754-1, iec 60754-2 |
smoke density | iec 61034-2 |
mud resistance | nek 606:2004 |
on request | cold bend and impact test (–40°c) csa c22.2 no 38-95 |