Helukabel 12 AWG 3 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3045X
Select gauge from drop-down menu for prices:
- Helukabel H05Z1Z1-F Halogen-Free Bare Copper Conductor Meter Marking Cable
- Helukabel 19 AWG 2 Cores H05Z1Z1-F Without GN-YE Conductor Halogen-Free Meter Marking Cable 3027X
- Helukabel 19 AWG 3 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3028X
- Helukabel 19 AWG 4 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3029X
- Helukabel 19 AWG 5 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3030X
- Helukabel 18 AWG 2 Cores H05Z1Z1-F Without GN-YE Conductor Halogen-Free Meter Marking Cable 3031X
- Helukabel 18 AWG 3 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3032X
- Helukabel 18 AWG 4 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3034X
- Helukabel 18 AWG 5 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3035X
- Helukabel 16 AWG 2 Cores H05Z1Z1-F Without GN-YE Conductor Halogen-Free Meter Marking Cable 3036X
- Helukabel 16 AWG 3 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3037X
- Helukabel 16 AWG 4 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3038X
- Helukabel 16 AWG 5 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3039X
- Helukabel 14 AWG 2 Cores H05Z1Z1-F Without GN-YE Conductor Halogen-Free Meter Marking Cable 3040X
- Helukabel 14 AWG 3 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3041X
- Helukabel 14 AWG 4 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3042X
- Helukabel 14 AWG 5 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3043X
- Helukabel 12 AWG 2 Cores H05Z1Z1-F Without GN-YE Conductor Halogen-Free Meter Marking Cable 3044X
- Helukabel 12 AWG 4 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3046X
- Helukabel 12 AWG 5 Cores H05Z1Z1-F With GN-YE Conductor Halogen-Free Meter Marking Cable 3047X
Technical data:
• Flexible halogen-free control cable adapted to DIN VDE 0285-525-3-11/DIN EN 50525-3-11
Temperature range:
• Flexing -5°C to +70°C
• Fixed installation -40°C to +70°C
Nominal voltage:
• U0/U 300/300 V
Test voltage:
• 2000 V
Breakdown voltage:
• Min. 4000 V
Minimum bending radius:
• 7,5x cable Ø
Radiation resistance:
• Up to 20x106 cJ/kg (up to 20 Mrad)
Cable structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of thermoplastic compound
• Core identification to DIN VDE 0293-308
• GN-YE conductor, 3 cores and above
• Outer sheath of thermoplastic compound
• Sheath colour by request
• with meter marking
Properties:
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
• Tested for flame retardation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
• Smoke density acc. to DIN VDE 0482-1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2
• Halogen-free acc. to DIN VDE 0285-525-1, DIN EN 50525-1
Note:
• G = with green-yellow conductor x = without green-yellow conductor
• Please complete the part number for these cables by adding the suffix for the colour required as per the list: 0 = approx.RAL 9005 black, 1 = approx.RAL 9003 withe, 2 = approx.RAL 5015 blue, 3 = approx.RAL 6018 green, 4 = approx.RAL 8003 brown, 5 = approx.RAL 1021 yellow, 6 = approx.RAL 3000 red, 7 = approx.RAL 2003 orange, 8 = approx.RAL 4005 violet, 9 = ca.RAL 7001/7032 grey, Further colours on request.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Application:
• These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For moderate mechanical demands in the house, kitchen and office, for house equipment in damp rooms (for example: washing machines, spin-dryers and refrigerators). Suitable for cooking and heating equipment, providing the cable is not in contact with hot components or heat radiation
Not suitable for:
• in high temperature areas (for example, in lighting equipment), outside buildings, in industrial or agricultural buildings, connection of electrical power tools. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
technical specification: | |
awg-no. | 12 |
no.cores x cross-sec. mm² | 3 G 4 |
outer ø app. mm | 11,3 |
cop. weight kg/km | 115,2 |
weight app. kg/km | 242,0 |
helukabel part number | 3045X |