Prysmian Cable 400 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables QXZ308A
Select gauge from drop-down menu for prices:
- Prysmian 3C AIRGUARD™ Low Voltage Commercial and Industrial Cables
- Prysmian Cable 14 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables
- Prysmian Cable 12 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables
- Prysmian Cable 10 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables
- Prysmian Cable 8 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q00580A
- Prysmian Cable 6 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q01580A
- Prysmian Cable 4 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q02580A
- Prysmian Cable 2 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q04580A
- Prysmian Cable 1 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q06580A
- Prysmian Cable 1/0 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q08580A
- Prysmian Cable 2/0 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q09580A
- Prysmian Cable 4/0 AWG Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0B580A
- Prysmian Cable 250 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0C580A
- Prysmian Cable 350 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0D580A
- Prysmian Cable 500 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0E580A
- Prysmian Cable 750 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables 306451A**
Conductor: Class B Compressed concentric strand soft drawn annealed copper or Class B Compact Series 8000 Aluminum per ASTM.
Insulation: High dielectric strength crosslinked polyethylene insulation to ICEA S-95-658/NEMA WC70 and UL Standard 44 for type XHHW-2.
Grounding Conducctors: Bare stranded copper conductor per UL, ICEA, and ASTM.
Assembly: Phase identified conductors cabled with fillers and a grounding conductor, forming a firm and cylindrical cable core.
Mechanical Protection: High strength and high crush resistant Air Bag™ layer extruded over the core assembly.
Chemical Protection: A layer of Drylam™ which consists of aluminum tape acting as a moisture barrier & a chemical resistant extruded polymer layer.
Jacket: Sunlight and moisture resistant polyvinyl chloride (PVC) jacket.
Description:
Three or four conductor cable with stranded copper or
aluminum conductors, extrude insulation system consisting
of high dielectric strength crosslinked polyethylene, cabled
with fillers and grounding conductors, foamed polymeric
layer for superior mechanical protection, longitudinally applied
aluminum tape bonded to an extruded oil and hydrocarbon
resistant polymeric layer, and overall moisture and sunlight
resistant black PVC jacket. Suitable for Class I Division2 locations.
Specifications and Ratings:
• ICEA S-95-658/NEMA WC 70 UL 44
• For CT USE Direct Buried Sunlight Resistant ER "Exposed Run” Rated Single Conductors Rated XHHW-2
• IEEE IEEE 383 Flame Test
• For 90°C continuous use in wet or dry conditions.
Options:
• Colored jacket
• Low Smoke Halogen Jacket
• Compact Conductors
technical specification: | |
conductor | 400 mcm cu |
insulation thickness (mils) | 65 |
ground wires (no) | 3 |
ground wires (size) | 7 awg |
conductor diamete (in) - (a) | 0.706 |
insulation diameter (in) - (b) | 0.85 |
overall jacket diameter (in) -(c) | 2.41 |
cable weight (lbs/kft) | 6008 |
minimum bending radius (in) | 17 |
† ampacity (amps) - (‡90°c) | 380 |
† † impedance (micro-ohms/foot) - (pos/neg seq) | 34 + j26 |
prysmian cable part number | QXZ308A |