Prysmian Cable 500 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0E580A

Prysmian Cable 500 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0E580A

Select gauge from drop-down menu for prices:

Prysmian Cable 500 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0E580A
Prysmian Cable 500 MCM Copper 600 Volt 3/C AIRGUARD Low Voltage Commercial and Industrial Cables Q0E580A

Conductor: Class B Compressed concentric strand soft drawn annealed copper or Class B Compact Series 8000 Aluminum per ASTM.

Insulation: High dielectric strength crosslinked polyethylene insulation to ICEA S-95-658/NEMA WC70 and UL Standard 44 for type XHHW-2. 

Grounding Conducctors: Bare stranded copper conductor per UL, ICEA, and ASTM. 

Assembly: Phase identified conductors cabled with fillers and a grounding conductor, forming a firm and cylindrical cable core.

Mechanical Protection: High strength and high crush resistant Air Bag™ layer extruded over the core assembly. 

Chemical Protection: A layer of Drylam™ which consists of aluminum tape acting as a moisture barrier & a chemical resistant extruded polymer layer. 

Jacket: Sunlight and moisture resistant polyvinyl chloride (PVC) jacket. 

Description:
Three or four conductor cable with stranded copper or aluminum conductors, extrude insulation system consisting of high dielectric strength crosslinked polyethylene, cabled with fillers and grounding conductors, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape bonded to an extruded oil and hydrocarbon resistant polymeric layer, and overall moisture and sunlight resistant black PVC jacket. Suitable for Class I Division2 locations.

Specifications and Ratings:
• ICEA S-95-658/NEMA WC 70 UL 44
• For CT USE Direct Buried Sunlight Resistant ER "Exposed Run” Rated Single Conductors Rated XHHW-2 
• IEEE IEEE 383 Flame Test 
• For 90°C continuous use in wet or dry conditions. 

Options: 
• Colored jacket
• Low Smoke Halogen Jacket 
• Compact Conductors

technical specification:
conductor 500 mcm cu
insulation thickness (mils) 65
ground wires (no) 3
ground wires (size) 6 awg
conductor diamete (in) - (a) 0.789
insulation diameter (in) - (b) 0.93
overall jacket diameter (in) -(c) 2.53
cable weight (lbs/kft) 7194
minimum bending radius (in) 18
† ampacity (amps) - (‡90°c) 430
† † impedance (micro-ohms/foot) - (pos/neg seq) 28 + j25
prysmian cable part number Q0E580A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.