General Cable Anaconda® Brand Type G-GC 6 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
Select gauge from drop-down menu for prices:
- General Cable Anaconda® Brand Type G-GC Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 4 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 3 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 2 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 1 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 1/0 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 2/0 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 3/0 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
- General Cable Anaconda® Brand Type G-GC 4/0 Gauge Power Flat Parallel Portable w/Ground-Check EPR CPE 2000 Volts Three Conductor
Product Details
The Anaconda® Brand Type G-GC 6 Gauge Power Cable is an industry standard mining cable that is listed as acceptable by MSHA, the Mining Safety and Health Administration. This cable offers the durability needed to take on heavy-duty tasks, and the flexibility needed to avoid becoming a hindrance to the project. The cable is flame-retardant, crush-resistant, and resistant to corrosive elements such as water, oil, chemicals, sunlight, and ozone.
The cable’s first line of protection is its outer jacket. The cable’s exterior is made of extra heavy-duty, lead-cured chlorinated polyethylene. CPE is a widely used for cable jacketing and insulation because it is resistant to oils, chemicals, high or low temperatures, and weather. CPE jacketed cables are also flame retardant and have great tensile strength. The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.
Type G –GC cables are three-conductor cables that include a neutral ground conductor. The cable uses coated, rope-lay-stranded, annealed copper wires that align with ASTM B172. The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. The annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.
Product Highlights:
v Anaconda® Brand Type G-GC Power Cable is listed as acceptable by MSHA.
v The cable’s flat construction keeps conductors from shifting under the cable’s jacket. The cable offers premium crush and impact resistance.
v Conductors are insulated in EPR, protecting them from sunlight, moisture, and oil.
v The cable’s CPE exterior jacket is flame retardant and adds tensile strength to the cable.
v Constructed with flexible, coated, rope-lay-stranded, annealed copper wires that align with ASTM standard B172.
technical specifications: | |
cond. size(awg) | 6 |
no. of cond. | 3 |
cond. strand | 133 |
nominal insulation thickness(inches) | 0.060 |
nominal insulation thickness(mm) | 1.5 |
grd. cond. size(awg) | 8 |
grd-check cond. size(awg)
|
8 |
nominal cable dimensions(inches) | 0.66 x 1.67 |
nominal cable dimensions(mm) | 16.8 x 42.4 |
copper weight(lbs/1000 ft) | 357 |
copper weight(kg/km) | 532 |
net weight(lbs/1000 ft) | 900 |
net weight(kg/km) | 1340 |
ampacity | 79 |
catalog number | 13162.650600 |