6-6-6 Erskine Triplex Aluminum URD Cable 600V
Select gauge from drop-down menu for prices:
- Triplex Aluminum URD Direct Burial Wire 600V
- 4-4-4 Vassar Triplex Aluminum URD Cable 600V
- 2-2-4 Stephens Triplex Aluminum URD Cable 600V
- 2-2-2 Ramapo Triplex Aluminum URD Cable 600V
- 1/0-1/0-2 Brenau Triplex Aluminum URD Cable 600V
- 1/0-1/0-1/0 Bergen Triplex Aluminum URD Cable 600V
- 2/0-2/0-2/0 Hunter Triplex Aluminum URD Cable 600V
- 2/0-2/0-1 Converse Triplex Aluminum URD Cable 600V
- 3/0-3/0-1/0 Hollins Triplex Aluminum URD Cable 600V
- 3/0-3/0-3/0 Rockland Triplex Aluminum URD Cable 600V
- 4/0-4/0-2/0 Sweetbriar Triplex Aluminum URD Cable 600V
- 4/0-4/0-4/0 Monmouth Triplex Aluminum URD Cable 600V
- 250-250-3/0 Pratt Triplex Aluminum URD Cable 600V
- 350-350-4/0 Wesleyan Triplex Aluminum URD Cable 600V
- 500-500-300 Holyoke Triplex Aluminum URD Cable 600V
- 500-500-350 Rider Triplex Aluminum URD Cable 600V
- 750-750-500 Fairfield Triplex Aluminum URD Cable 600V
Description:
Erskine 6-6-6 is among the group of Aluminum Triplex URD Cable. All the three conductors of this cable have 6 AWG gauge sizes. The phase conductors are printed for identification while the neutral is stripped. #6 triplex cable works effectively at 600V and below, and optimal temperature of 90°C. The cable is used for service entrance and underground secondary circuits. If directly buried into the ground, it serves up to 95 amps but if ducts are used, it serves up to 70 amps.
Applications:
#6 Triplex wire is specifically designed for underground distribution systems. However in extreme environmental conditions, the cross-linked polyethylene is used since it can withstand temperatures of up to 90°C.
Conductors:
They are made of aluminum alloy which are compressed in 1350-H19. Only 99.5% of the conductor is made of aluminum the rest is made of zinc, copper and silicon. This is to strengthen the conductors.
Insulation:
The insulation is made of standard Cross-linked polyethylene.
Features:
• Can resist high temperatures of up to 90°C
• Corrosion resistant conductors
• Heat and moisture resistant insulation
• Lead free triplex wire
• 600 volt URD cable
Standards:
• ASTM B-901
• ICEA S-105-692
• Federal Specification J-C-30B
• RUS Accepted
Technical Specifications: | |
Phase Conductor Size AWG: | 6 |
Phase Conductor Stranding: | 7 |
Phase Conductor Insulation Thickness: | 60 mls |
Base Neutral Messenger Size AWG: | 6 |
Base Neutral Strand: | 7 |
Diameter Single Phase Conductor (Mils): | 298 |
Diameter Complete Cable (O.D.) (Mils): | 644 |
Weight Per 1000ft Total (Lbs.): | 134 |
Allowable Ampacity 90C (Amps): | 95 |
Allowable Ampacity in Ducts (Amps): | 70 |