2-2-2 Ramapo Triplex Aluminum URD Cable 600V
Select gauge from drop-down menu for prices:
- Triplex Aluminum URD Direct Burial Wire 600V
- 6-6-6 Erskine Triplex Aluminum URD Cable 600V
- 4-4-4 Vassar Triplex Aluminum URD Cable 600V
- 2-2-4 Stephens Triplex Aluminum URD Cable 600V
- 1/0-1/0-2 Brenau Triplex Aluminum URD Cable 600V
- 1/0-1/0-1/0 Bergen Triplex Aluminum URD Cable 600V
- 2/0-2/0-2/0 Hunter Triplex Aluminum URD Cable 600V
- 2/0-2/0-1 Converse Triplex Aluminum URD Cable 600V
- 3/0-3/0-1/0 Hollins Triplex Aluminum URD Cable 600V
- 3/0-3/0-3/0 Rockland Triplex Aluminum URD Cable 600V
- 4/0-4/0-2/0 Sweetbriar Triplex Aluminum URD Cable 600V
- 4/0-4/0-4/0 Monmouth Triplex Aluminum URD Cable 600V
- 250-250-3/0 Pratt Triplex Aluminum URD Cable 600V
- 350-350-4/0 Wesleyan Triplex Aluminum URD Cable 600V
- 500-500-300 Holyoke Triplex Aluminum URD Cable 600V
- 500-500-350 Rider Triplex Aluminum URD Cable 600V
- 750-750-500 Fairfield Triplex Aluminum URD Cable 600V
2.04:
Ramapo 2-2-2 Triplex is a special type of Aluminum URD cable fitted with three Aluminum conductors each of 2 Gauge sizes. The insulators are printed on the surface and the neutral cable stripped for easy identification. In the applications like service entry and secondary underground circuiting, as long as the temperatures do not exceed 90°C and a voltage of 600 volts maximum. When directly buried, the optimal current it transmits is 165 amps but if ducts are used the current drops to 120 amps.
Applications:
2-2-2 Aluminum Underground Distribution Cable specifically designed for underground distribution systems. In extreme environmental conditions, the cross-linked polyethylene is used since it can withstand temperatures of up to 90°C.
Conductors:
They are made of aluminum alloy which are compressed in 1350-H19. Only 99.5% of the conductor is made of aluminum the rest is made of zinc, copper and silicon.
Insulation:
The insulation is made of standard polyethylene or cross-linked polyethylene.
Features:
• Can resist high temperatures of up to 90°C
• Corrosion resistant conductors
• Heat and moisture resistant insulation
• Lead free triplex wire
• 600 volt URD cable
Standards:
• ASTM B-901
• ICEA S-105-692
• Federal Specification J-C-30B
• RUS Accepted
Technical Specifications: | |
Phase Conductor Size AWG: | 2 |
Phase Conductor Stranding: | 7 |
Phase Conductor Insulation Thickness: | 60 mls |
Base Neutral Messenger Size AWG: | 2 |
Base Neutral Strand: | 7 |
Diameter Single Phase Conductor (Mils): | 403 |
Diameter Complete Cable (O.D.) (Mils): | 870 |
Weight Per 1000ft Total (Lbs.): | 278 |
Allowable Ampacity 90C (Amps): | 165 |
Allowable Ampacity in Ducts (Amps): | 120 |