Rust 250-250-250-3/0 Quadruplex Aluminum URD Cable
Select gauge from drop-down menu for prices:
- Quadruplex Aluminum URD Direct Burial Wire 600V
- Tulsa 4-4-4-4 Quadruplex Aluminum URD Cable
- Dyke 2-2-2-4 Quadruplex Aluminum URD Direct Burial Cable
- Wittenberg 2-2-2-2 Quadruplex Aluminum URD Cable
- Notre Dame 1/0-1/0-1/0-2 Quadruplex Aluminum URD Cable
- Purdue 1/0-1/0-1/0-1/0 Quadruplex Aluminum URD Cable
- Syracuse 2/0-2/0-2/0-1 Quadruplex Aluminum URD Cable
- Lafayette 2/0-2/0-2/0-2/0 Quadruplex Aluminum URD Cable
- Swarthmore 3/0-3/0-3/0-1/0 Quadruplex Aluminum URD Cable
- Davidson 3/0-3/0-3/0-3/0 Quadruplex Aluminum URD Cable
- Wake Forest 4/0-4/0-4/0-2/0 Quadruplex Aluminum URD Cable
- Earlham 4/0-4/0-4/0-4/0 Quadruplex Aluminum URD Cable
- Slippery Rock 350-350-350-4/0 Quadruplex Aluminum URD Cable
- Wofford 500-500-500-350 Quadruplex Aluminum URD Cable
- Westminster 750-750-750-500 Quadruplex Aluminum URD Cable
- Windham 750-750-750-500 Quadruplex Aluminum URD Wire
Description:
Rust 250-250-250-3/0 is a type of Aluminum URD power transmission cable that is designed for underground distribution of secondary circuits. The cable has three phase conductors, each of 250 MCM and a single neutral conductor of 3/0 AWG size. The cable is rated for 600 volts. The cable operates at 330 amps but when In Ducts it supplies 280 amps.
Applications:
250 MCM Rust Aluminum wire is used for underground power supply systems in residential zones. The cable can used for direct burial or can be installed in conduits or ducts which channel the cable to a given direction. It can also be used in wet and dry locations.
Conductors:
The conductors are made of aluminum alloy 1350-H19. The conductors are each stranded for flexibility.
Insulation:
It is made of cross-linked polyethylene. It can withstand high temperatures of 90°C.
Features:
• It has sequential footage markings
• Heat and moisture resistant
• Approved for use by international standards
• Temperatures of 90°C
Standards:
• Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
• B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
• Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
• "USE-2" per UL 854 available upon request.
Technical Specifications: | |
Phase Conductor Size AWG: | 250 |
Phase Conductor Stranding: | 37 |
Phase Conductor Insulation Thickness: | 95 mls |
Base Neutral Messenger Size AWG: | 3/0 |
Base Neutral Strand: | 17 |
Diameter Single Phase Conductor (Mils): | 603 |
Diameter Complete Cable (O.D.) (Mils): | 1456 |
Weight Per 1000ft Total (Lbs.): | 868 |
Allowable Ampacity 90C (Amps): | 330 |
Allowable Ampacity in Ducts (Amps): | 280 |