Tulsa 4-4-4-4 Quadruplex Aluminum URD Cable
Select gauge from drop-down menu for prices:
- Quadruplex Aluminum URD Direct Burial Wire 600V
- Dyke 2-2-2-4 Quadruplex Aluminum URD Direct Burial Cable
- Wittenberg 2-2-2-2 Quadruplex Aluminum URD Cable
- Notre Dame 1/0-1/0-1/0-2 Quadruplex Aluminum URD Cable
- Purdue 1/0-1/0-1/0-1/0 Quadruplex Aluminum URD Cable
- Syracuse 2/0-2/0-2/0-1 Quadruplex Aluminum URD Cable
- Lafayette 2/0-2/0-2/0-2/0 Quadruplex Aluminum URD Cable
- Swarthmore 3/0-3/0-3/0-1/0 Quadruplex Aluminum URD Cable
- Davidson 3/0-3/0-3/0-3/0 Quadruplex Aluminum URD Cable
- Wake Forest 4/0-4/0-4/0-2/0 Quadruplex Aluminum URD Cable
- Earlham 4/0-4/0-4/0-4/0 Quadruplex Aluminum URD Cable
- Rust 250-250-250-3/0 Quadruplex Aluminum URD Cable
- Slippery Rock 350-350-350-4/0 Quadruplex Aluminum URD Cable
- Wofford 500-500-500-350 Quadruplex Aluminum URD Cable
- Westminster 750-750-750-500 Quadruplex Aluminum URD Cable
- Windham 750-750-750-500 Quadruplex Aluminum URD Wire
Description:
Tulsa 4-4-4-4 Aluminum wire is an underground electricity cable that also works as a service entrance cable and cabling for underground secondary circuits. The four conductors of this cable are 4 AWG sizes. This makes it a 3 phase cable and the 4th wire is a neutral wire has yellow stripes. The cable is a medium duty service because of its 90°C temperature rating and 600 volts. It has an ampacity of 120 amps when buried and 85 amps when used in ducts.
Applications:
#4 Tulsa Quadruplex URD Cable is used for underground power supply systems in residential zones. The cable can used for direct burial or can be installed in conduits or ducts which channel the cable to a given direction. Furthermore it can also be used in wet and dry locations.
Conductors:
The conductors are made of aluminum alloy 1350-H19. The conductors are each stranded for flexibility.
Insulation:
It is made of cross-linked polyethylene. It can withstand high temperatures of 90°C.
Features:
• It has sequential footage markings
• Heat and moisture resistant
• Approved for use by international standards
• Temperatures of 90°C
Standards:
• Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
• B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
• Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
• "USE-2" per UL 854 available upon request.
Technical Specifications: | |
Phase Conductor Size AWG | 4 |
Phase Conductor Stranding | 7 |
Phase Conductor Insulation Thickness | 60 mls |
Base Neutral Messenger Size AWG | 4 |
Base Neutral Strand | 7 |
Diameter Single Phase Conductor (Mils) | 345 |
Diameter Complete Cable (O.D.) (Mils) | 833 |
Weight Per 1000ft Total (Lbs.) | 255 |
Allowable Ampacity 90C (Amps) | 120 |
Allowable Ampacity in Ducts (Amps) | 85 |
I placed my order online and it was delivered on time at a good price. I would recommend them.
I made the order late on Friday & it shipped on Monday & arrived UPS Ground on Friday at about noon. That is a great turnaround considering the shortages going on everywhere.
Quick shipping and packaged neatly.
Prompt shipment and website is very easy to navigate, will recommend this Company to all the Electrical Contractors !
I placed my order online and it was delivered on time at a good price. I would recommend them.
I made the order late on Friday & it shipped on Monday & arrived UPS Ground on Friday at about noon. That is a great turnaround considering the shortages going on everywhere.
Quick shipping and packaged neatly.
Prompt shipment and website is very easy to navigate, will recommend this Company to all the Electrical Contractors !