4-4-4 Vassar Triplex Aluminum URD Cable 600V
Select gauge from drop-down menu for prices:
- Triplex Aluminum URD Direct Burial Wire 600V
- 6-6-6 Erskine Triplex Aluminum URD Cable 600V
- 2-2-4 Stephens Triplex Aluminum URD Cable 600V
- 2-2-2 Ramapo Triplex Aluminum URD Cable 600V
- 1/0-1/0-2 Brenau Triplex Aluminum URD Cable 600V
- 1/0-1/0-1/0 Bergen Triplex Aluminum URD Cable 600V
- 2/0-2/0-2/0 Hunter Triplex Aluminum URD Cable 600V
- 2/0-2/0-1 Converse Triplex Aluminum URD Cable 600V
- 3/0-3/0-1/0 Hollins Triplex Aluminum URD Cable 600V
- 3/0-3/0-3/0 Rockland Triplex Aluminum URD Cable 600V
- 4/0-4/0-2/0 Sweetbriar Triplex Aluminum URD Cable 600V
- 4/0-4/0-4/0 Monmouth Triplex Aluminum URD Cable 600V
- 250-250-3/0 Pratt Triplex Aluminum URD Cable 600V
- 350-350-4/0 Wesleyan Triplex Aluminum URD Cable 600V
- 500-500-300 Holyoke Triplex Aluminum URD Cable 600V
- 500-500-350 Rider Triplex Aluminum URD Cable 600V
- 750-750-500 Fairfield Triplex Aluminum URD Cable 600V
Description:
Vassar 4-4-4 Triplex cable which has two phase conductors and one neutral wire twisted or laid parallel to each other. The conductors are made of aluminum alloy which is further insulated with cross-linked polyethylene. The cable is used in residential zones for secondary power distribution. It can be installed in conduits, ducts or as direct burial wire. It has Ampacity of 125 however if installed inducts it can only allow 90 amps.
Applications:
#4 Vassar URD Cable is designed for secondary distribution. Secondary distribution occurs after the power has been received by the transformer and reduced to utilization voltage, a safe voltage for residential use. This cable can be installed in ducts or be used in direct burial.
Conductors:
They are made of aluminum alloy which are compressed in 1350-H19. Only 99.5% of the conductor is made of aluminum the rest is made of zinc, copper and silicon. This is to strengthen the conductors.
Insulation:
The insulation is made of standard polyethylene or cross-linked polyethylene.
Features:
• Can resist high temperatures of up to 90°C
• Corrosion resistant conductors
• Heat and moisture resistant insulation
• Lead free triplex wire
• 600 volt URD cable
Standards:
• ASTM B-901
• ICEA S-105-692
• Federal Specification J-C-30B
• RUS Accepted
Technical Specifications: | |
Phase Conductor Size AWG: | 4 |
Phase Conductor Stranding: | 7 |
Phase Conductor Insulation Thickness: | 60 mls |
Base Neutral Messenger Size AWG: | 4 |
Base Neutral Strand: | 7 |
Diameter Single Phase Conductor (Mils): | 345 |
Diameter Complete Cable (O.D.) (Mils): | 745 |
Weight Per 1000ft Total (Lbs.): | 191 |
Allowable Ampacity 90C (Amps): | 125 |
Allowable Ampacity in Ducts (Amps): | 90 |