Belden 1227A1 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Belden 1227A1 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1227A1 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Precio habitual $0.24 Oferta /per Foot

Belden 1227A1 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Description:
• CAT3 (16MHz), 2-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 24 AWG solid bare copper conductors, Polyolefin insulation, PVC jacket.

Insulation:
• Material: PP - Polypropylene

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.173

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 75°C
• Bulk Cable Weight: 13 lbs/1000 ft.
• Max. Recommended Pulling Tension: 15 lbs.
• Min. Bend Radius/Minor Axis: 1 in.
• Min. Bend/Installation: 1.700 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, UL444
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 802.3 10BaseT, 100BaseT4
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: NEMA WC-63 Category 3

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 70
• Nominal Delay (ns/ft): 1.5
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5

Flame Test:
• UL Flame Test: UL1666 Riser
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 1243A2

technical specification:
awg 24
# pairs 2
stranding solid
no. of conductors 4
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) -
belden cable part number 1227A1

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.