Belden 1245A2 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable

Belden 1245A2 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1245A2 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable

Precio habitual $0.45 Oferta /per Foot

Belden 1245A2 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable

Description:
• CAT3, 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 24 AWG solid bare copper conductors, LS-PVC insulation, LS-PVC jacket.

Insulation:
• Material: LS PVC - Low Smoke Polyvinyl Chloride

Outer Jacket:
• Material: LS-PVC - Low Smoke Polyvinyl Chloride

Mechanical Characteristics (Overall):
• Installation Temperature Range: 0°C To +60°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 20 lbs/1000 ft.
• Max. Recommended Pulling Tension: 25 lbs.
• Min. Bend Radius/Minor Axis: 1 in.
• Min. Bend/Installation: 1.600 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 802.3 10BaseT, 100BaseT4
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 06/01/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: 568-B.2 Category 3
• Other Specification: NEMA WC-63 Category 3, UL verified to TIA/EIA-568-B.2, Category 3.

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 19
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 61
• Nominal Delay (ns/ft): 1.5
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Sunlight Resistance: No

Plenum/Non-Plenum:
• Non-Plenum Number: 1229A1

technical specification:
awg 24
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.157 x 0.170
belden cable part number 1245A2

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question