Belden 1243A2 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Category 3 Cable
- Belden DIW2 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden 1227A1 Cable 24 AWG 2 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DFLEX3 Cable 24 AWG 3 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LSPVC Jacket Cable
- Belden DIW3 Cable 24 AWG 3 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DFLEX4 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LSPVC Jacket Cable
- Belden 1245A2 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW4 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden 1229A1 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DIW6 Cable 24 AWG 6 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DIW12 Cable 24 AWG 12 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DPLN25 Cable 24 AWG 25 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW25 Cable 24 AWG 25 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden 1232A1 Cable 24 AWG 25 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DPLN50 Cable 24 AWG 50 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW50 Cable 24 AWG 50 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DPLN100 Cable 24 AWG 100 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW100 Cable 24 AWG 100 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DPLN200 Cable 24 AWG 200 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW200 Cable 24 AWG 200 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden DPLN300 Cable 24 AWG 300 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper LS-PVC Jacket Cable
- Belden DIW300 Cable 24 AWG 300 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable
- Belden ATMM25 Cable 24 AWG 25 Pairs Category 3 Nonbonded-Pair Armored Multi Conductor F/UTP-Foil Shield Solid BC Overall PVC Jacket Cable
- Belden ATMM50 Cable 24 AWG 50 Pairs Category 3 Nonbonded-Pair Armored Multi Conductor F/UTP-Foil Shield Solid BC Overall PVC Jacket Cable
- Belden ATMM100 Cable 24 AWG 100 Pairs Category 3 Nonbonded-Pair Armored Multi Conductor F/UTP-Foil Shield Solid BC Overall PVC Jacket Cable
- Belden ATMM200 Cable 24 AWG 200 Pairs Category 3 Nonbonded-Pair Armored Multi Conductor F/UTP-Foil Shield Solid BC Overall PVC Jacket Cable
- Belden ATMM400 Cable 24 AWG 400 Pairs Category 3 Nonbonded-Pair Armored Multi Conductor F/UTP-Foil Shield Solid BC Overall PVC Jacket Cable
Description:
• CAT3, 2-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 24 AWG solid bare copper conductors, LS-PVC insulation, LS-PVC jacket.
Insulation:
• Material: LS PVC - Low Smoke Polyvinyl Chloride
Outer Jacket:
• Trade Name: Flamarrest
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.135
Mechanical Characteristics (Overall):
• Installation Temperature Range: 0°C To +75°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 12 lbs/1000 ft.
• Max. Recommended Pulling Tension: 15 lbs.
• Min. Bend Radius/Minor Axis: 1 in.
• Min. Bend/Installation: 1.350 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 802.3 10BaseT, 100BaseT4
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 06/01/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: 568-B.2 Category 3
• Other Specification: NEMA WC-63 Category 3, UL verified to TIA/EIA-568-B.2, Category 3.
Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 19
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 61
• Nominal Delay (ns/ft): 1.5
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5
Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• CSA Flame Test: FT6
Plenum/Non-Plenum:
• Non-Plenum Number: 1227A1
technical specification: | |
awg | 24 |
# pairs | 2 |
stranding | solid |
no. of conductors | 4 |
conductor material | bare copper |
outer shield - type | - |
outer shield - material | unshielded |
overall cable - nominal diameter (in.) | - |
belden cable part number | 1243A2 |