• Security & Commercial Audio Cable, Plenum-CMP, 2-22 AWG stranded tinned copper pairs with Flamarrest® insulation, individually shielded with Beldfoil® shield, Flamarrest® jacket

Insulation:
• Trade Name: Flamarrest®
• Material: F-R PVC - Flame Retardant Polyvinyl Chloride

Inner Shield:
• Trade Name: Beldfoil® Z-Fold®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 24

Outer Jacket:
• Trade Name: Flamarrest®
• Material: F-R PVC - Flame Retardant Polyvinyl Chloride

Pair Lay Length and Direction:
• Twists (twist/ft): 8

Usage (Overall):
Applications:
• Sound and Audio Systems, Intercom and PA Systems, Security Systems, Power-Limited Control Systems

Mechanical Charactertistics (Overall):
• Operating Temperature Range: 0°C To +75°C
• Bulk Cable Weight: 19 lbs/1000 ft.
• Max. Recommended Pulling Tension: 27 lbs.
• Min. Bend Radius/Minor Axis: 1.600 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/30/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 34
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 14.7
• Nom. Inner Shield DC Resistance @ 20°C (Ohm/1000 ft): 15
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.8 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL910 Steiner Tunnel
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Non-Plenum Number: 8723

technical specification:
awg 22
# conductors -
stranding 7x30
no. of conductors 4
conductor material tinned copper
dia. (mm) -
outer shield - type -
outer shield - material -
overall cable- nominal dia, (mm.) 4.0132
belden cable part number 1325A