Belden 9180 Cable 26 AWG Audio Single Pair Stranded 7x34 TC Rated CMR PVC Jacket Cable

Belden 9180 Cable 26 AWG Audio Single Pair Stranded 7x34 TC Rated CMR PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9180 Cable 26 AWG Audio Single Pair Stranded 7x34 TC Rated CMR PVC Jacket Cable

Precio habitual $0.87 Oferta /per Foot

Belden 9180 Cable 26 AWG Audio Single Pair Stranded 7x34 TC Rated CMR PVC Jacket Cable

Description:
• 110 Ohm, 26 AWG stranded (7x34) .018” TC conductors, Datalene® insulation, twisted pair, Beldfoil® shield (100% coverage), 26 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Trade Name: Datalene®
• Material: FHDPE - Foam High Density Polyethylene
• Dia. (mm): 1.2446

Outer Shield Drain Wire AWG:
• AWG: 26
• Stranding: 7x34
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +75°C
• UL Tempeature Rating: 75°C
• Bulk Cable Weight: 14.882 Kg/Km
• Max. Recommended Pulling Tension: 46.706 N
• Min. Bend Radius/Minor Axis: 38.100 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: AES/EBU

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 110
• Nom. Inductance (μH/m): 0.75463
• Nom. Capacitance Conductor to Conductor (pF/m): 42.653
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 85.306
• Nominal Velocity of Propagation (VP %): 76
• Nominal Delay (ns/m): 4.39654
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 122.381
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 75.7911
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.9 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 26
# conductors -
stranding 7x34
no. of conductors 2
conductor material tinned copper
dia. (mm) 0.4826
outer shield - type tape
outer shield - material aluminum foil-polyester tape w/shorting fold
overall cable- nominal dia, (mm.) 3.658
belden cable part number 9180

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question