Description:
• Security, Pro Audio & Intercom Cable, Plenum-CMP, 16-22 AWG stranded bare copper pairs with FEP insulation, Individually Beldfoil® shielded and PVDF jacket with ripcord

Insulation:
• Trade Name: Teflon®
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.254
• Dia. (mm): 1.245

Inner Shield:
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 24
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVDF - Fluorocopolymer
• Nom. Wall Thickness (mm): 0.432
• Outer Jacket Ripcord: Yes

Pair Lay Length and Direction):
• Lay Length (mm): 34.925
• Twist (twist/ft): 6.900

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +150°C
• UL Tempeature Rating: 75°C
• Bulk Cable Weight: 150 lbs/1000 ft.
• Max. Recommended Pulling Tension: 324.200 lbs.
• Min. Bend Radius/Minor Axis: 4.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 50
• Nom. Inductance (μH/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft): 27.5
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft: 49.5
• Nominal Velocity of Propagation (VP %): 69
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 16.4
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 15.3
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• C(UL) Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes

technical specification:
awg 22
# conductors -
stranding 7x30
no. of conductors 32
conductor material bare copper
dia. (mm) 0.7366
outer shield - type -
outer shield - material unshielded
overall cable- nominal dia, (mm.) 11.608
belden cable part number 6549PA