General Cable HVTECK® 3C 3/0 AWG 115 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 5 kV CSA

General Cable HVTECK® 3C 3/0 AWG 115 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 5 kV CSA

Select gauge from drop-down menu for prices:

HVTECK 3C 3/0 AWG 115 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 5 kV CSA

Conductor: 6 AWG thru 1000 kcmil bare copper compact Class B strand

Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor

Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)

Insulation Shield:
• A semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
• Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Aluminum Interlocked Armor (AIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For wiring in all hazardous locations when used with certified HL cable glands
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)

Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 131 and No. 174
• CSA Standard C68.10

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
• ICEA T-29-520 (210,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specifications:
cond. size (awg/kcmil) 3/0
no. of cond 3
ground wire size (awg) 4
nominal diameter (over)(insulation in inches) 0.70
nominal diameter (over)(insulation in mm) 17.7
nominal diameter (over)(insulation shield in inches) 0.76
nominal diameter (over)(insulation shield in mm) 19.3
nominal diameter (over)(inner jacket in inches) 1.90
nominal diameter (over)(inner jacket in mm) 48.3
nominal diameter (over)(armor in inches) 2.19
nominal diameter (over)(armor in mm) 55.7
nominal diameter (over)(cable in inches) 2.29
nominal diameter (over)(cable in mm) 58.2
copper weight(lbs/1000 ft) 1796
copper weight(kg/km) 2673
net weight w/armor(lbs/1000 ft in al) 3360
net weight w/armor(lbs/1000 ft in steel) 4240
net weight w/armor(kg/km in al) 5000
net weight w/armor(kg/km in steel) 6310
outdoor ampacity** (40?c ambient) 242
catalog number 17496.755300*