Applications:
NM-B wire cable may be used for either exposed or covered circuits in dry locations requiring voltages of up to 600 volts, and temperatures not exceeding 90°C as per the regulations of NEC. Primarily, this cable is used for wiring residential buildings at branched circuits. It can be installed in the air voids of masonry blocks as long as the block walls or tile walls are not wet.
Conductors:
• compressed and stranded conductor
• Conductor sizes range from 14 AWG size through to 2 AWG size.
• Made of 2, 3, or 4 copper conductors, depending on the power loads required.
Insulation:
• insulated using a polyvinyl Chloride (PVC).
Jacket:
• Nylon Jacket that’s designed for easy pulling for easy installation.
Features:
• Solid copper wire conductors
• Highly flexible
• Maximum operating temperature of 90°C
• Rated 600v
• Sheathed
• Heat and sunlight resistant insulation and jacket
• Ripcord included for easier separation of jacket during termination.
Standards and compliances:
• Type NM-B cable meets or exceeds UL Standard 83
• UL Standard 719
• Federal Specification A-A-59544 and requirements of the National Electrical Code.
• NEC Article 725
• Type CL2 Meets FT4 / IEEE 1202 Vertical Tray Flame Test
• RoHS 2 Chemical Limit Compliant
Size AWG | Conductor | Weight Per 1000ft(Lbs.) |
Allowable Ampacity 90°C(Amps) |
Action |
14 | 2 | 57 | 15 | Add to Cart |
12 | 2 | 82 | 20 | Add to Cart |
10 | 2 | 124 | 30 | Add to Cart |
8 | 2 | 186 | 40 | Add to Cart |
6 | 2 | 255 | 55 | Add to Cart |
14 | 3 | 74 | 15 | Add to Cart |
12 | 3 | 107 | 20 | Add to Cart |
10 | 3 | 164 | 30 | Add to Cart |
8 | 3 | 253 | 40 | Add to Cart |
6 | 3 | 357 | 55 | Add to Cart |
4 | 3 | 560 | 70 | Add to Cart |
2 | 3 | 816 | 95 | Add to Cart |
14 | 2/2 | 91 | 15 | Request a Quote |
14 | 4 | 91 | 15 | Request a Quote |
12 | 2/2 | 132 | 20 | Request a Quote |
12 | 4 | 132 | 20 | Request a Quote |