12 AWG 3C Type P Unarmored Power Cable 600V/1000V
Select gauge from drop-down menu for prices:
- Type P Multi Conductor Unarmored Power Cable 600V/1000V
- 16 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 14 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 10 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 8 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 6 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 4 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 2 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 1 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 1/0 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 2/0 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 3/0 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 4/0 AWG 3C Type P Unarmored Power Cable 600V/1000V
- 262 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 313 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 373 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 444 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 535 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 646 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 777 MCM 3C Type P Unarmored Power Cable 600V/1000V
- 16 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 14 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 12 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 10 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 8 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 6 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 4 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 2 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 1 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 1/0 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 2/0 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 3/0 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 4/0 AWG 4C Type P Unarmored Power Cable 600V/1000V
- 262 MCM 4C Type P Unarmored Power Cable 600V/1000V
- 313 MCM 4C Type P Unarmored Power Cable 600V/1000V
- 373 MCM 4C Type P Unarmored Power Cable 600V/1000V
- 444 MCM 4C Type P Unarmored Power Cable 600V/1000V
- 535 MCM 4C Type P Unarmored Power Cable 600V/1000V
- 646 MCM 4C Type P Unarmored Power Cable 600V/1000V
Description:
12 AWG 3 Conductor 12/3 unarmored Type P Power cable is designed of soft annealed stranded tinned copper and is flexible for easy installation. It is used in operations of between 600 volts and 1000 volts. This cable can serve 33 amps of current at Temperature of 110°C
Applications
• For use in demanding environments of offshore drilling and petroleum facilities
• The cable is used for power distribution within circuits in the marine environments. It may be used to wire lighting equipment, control, and communication systems. The cable can be used in A/C motor power, transformer feeders, distribution panel feeders, light fixtures, lighting panels, remote motor controls, and plugs or receptacles.
Insulation:
• Flame retardant cross-linked polyolefin
Jacketing:
• Arctic Grade Black PVC jacket capable of withstanding elements like oil, sunlight, chemical substances, and flame. It is also abrasion resistant.
Features
• High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.
• Lower dielectric constant and higher insulation resistance reduces electrical losses.
• Excellent resistance to moisture produces stable electrical properties throughout the life of the cable.
• In fire conditions, non-chlorinated flame retardant system produces less toxic and less corrosive gasses.
• Dual certified IEEE 1580 Type P and UL 1309/CSA C22.2 No. 245 Type X110.
• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C
• Severe cold durability: exceeds CSA cold bend/cold impact (-40/-35° C)
• Flame retardant: IEC 60332-3 Category A and IEEE 1202
Technical Specifications: | |
Catalog Number | HW267 01203 |
Size AWG | 12 |
mm2 | 3.3 |
Nominal Diameter (inches) | 0.445 |
Weight (lbs/Mft.) | 133 |
DC Resistance at 25° C (Ohms/1000 ft.) | 1.826 |
AC Resistance at 110°C, 60 Hz (Ohms/1000 ft.) | 2.424 |
Inductive Reactance (Ohms/1000 ft.) | 0.034 |
Voltage Drop at 110°C (Volts/Amp/1000 ft.) | 3.390 |
Opt. Uninsulated Grounding Cond. Size AWG 1 | -- |
Ampacity 110°C | 33 |
Ampacity 100°C | 31 |
Ampacity 95°C | 27 |