General Cable 22 AWG 25 Conductor Foil/Braid Shield® Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
Select gauge from drop-down menu for prices:
- General Cable Multi Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 3 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 4 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 5 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 6 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 7 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 8 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 9 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 10 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 15 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
- General Cable 22 AWG 20 Conductor Foil/Braid® Shield Cable UL 2464 NEC/CEC Type CMR CMG UL/CSA
Product Details
Conductor: 22 AWG fully annealed stranded tinned copper per ASTM B33
Insulation:
• Premium-grade, coIor-coded S-R PVC per UL 1061
• Color code: See chart below
Shield:
• 100% Flexfoil® aluminum/polyester with 25% overlap, minimum, foil facing out
• 65% tinned copper braid
Jacket:
• PVC, gray
• Temperature range: ?20°C to +80?C
Applications:
• Computers
• Industrial equipment
• Data transmission
• Control circuits
• Suitable for EIA RS-232 applications
• Suggested voltage rating: 300 volts
Compliances:
• NEC Article 800 Type CMR (UL: 75?C)
• UL Style 2464 (UL: 80°C, 300 V)
• CSA CMG (CSA: 60?C)
• RoHS Compliant Directive 2011/65/EU
• Designed to meet UL 70,000 BTU Vertical Tray Flame Test
• Passes CSA CMG Flame Test
• CE: Low Voltage Directive (LVD) 2006/95/EC
• Assists system designers in meeting FCC Docket 20780 demands
Packaging: Please contact Customer Service for packaging and color options
technical specification: | |
awg size | 22 |
no. of cond. | 25 |
cond. strand
|
7/30 |
nominal insulation thickness(inches) | 0.010 |
nominal insulation thickness(mm) | 0.25 |
nominal jacket thickness(inches) | 0.032 |
nominal jacket thickness(mm) | 0.81 |
nominal o.d.(inches) | 0.391 |
nominal o.d.(mm) | 9.93 |
nominal dcr ω/kft@20?c(cond.) | 16.6 |
nominal dcr ω/kft@20?c(shld.) | 2.7 |
nominalcap.*pf/ft(a) | 36.0 |
nominalcap.*pf/ft(b) | 66.0 |
catalog number | C0981A |