Amercable CIR Instrumentation Cable 16 AWG 1 Pair Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 610
Select gauge from drop-down menu for prices:
- Amercable CIR Instrumentation Cable Gexol Insulated Individually Shielded Pairs/Triads 0.6/1kV Rated 90C 37-102
- Amercable CIR Instrumentation Cable 16 AWG 2 Pairs Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 611
- Amercable CIR Instrumentation Cable 16 AWG 4 Pairs Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 613
- Amercable CIR Instrumentation Cable 16 AWG 8 Pairs Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 616
- Amercable CIR Instrumentation Cable 16 AWG 12 Pairs Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 618
- Amercable CIR Instrumentation Cable 16 AWG 24 Pairs Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 699
- Amercable CIR Instrumentation Cable 16 AWG 1 Triad Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 668
- Amercable CIR Instrumentation Cable 16 AWG 4 Triads Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102- 698
- Amercable CIR Instrumentation Cable 16 AWG 8 Triads Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102-677
- Amercable CIR Instrumentation Cable 16 AWG 12 Triads Gexol Insulated Individually Shielded 0.6/1kV Rated 90C 37-102-734
Conductor: Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.
Insulation: GEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V.
Pairs/Triads: Each pair/triad is twisted with a bare tinned drain wire. Each pair/triad is shielded with polyester-backed aluminum foil tape to afford 100% coverage. Pair to pair, or triad to triad, isolation – plus overall shielding – is provided.
Safer to Handle: CIR® has no sharp metal armor edges that imperil worker’s hands during splicing and installation of connectors
Jacket: A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/ CSA 245 and IEEE 1580.
Application: Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions.
Features:
• Complies with the requirements for TC-ER-HL per UL 2225*
• Exceeds CSA cold bend / cold impact (-40°C / -35°C)
• Gas & vapor tight – impervious to water & air
• Smaller bend radius (up to 40% smaller) than Type MC
• Reduced tray fill (up to 35% less) compared to Type MC
• Considerably more flexible than Type MC
• Reduced installation time and cost compared to Type MC
• Glands for this product cost up to 50% LESS than those for Type MC(*cables up to 1” in diameter)
technical specification: | |
conductor size(awg) | 16 |
conductor size(mm2) | 1.3 |
pairs | 1 |
triads | - |
nominal diameter(inches) | 0.437 |
weight(lbs/1000 ft.) | 106 |
dc resistance 20°c(ohms/1000 ft.) | 4.52 |
mutual capacitance (nf/1000 ft.) | 32 |
inductance (mh/1000 ft.) | 0.20 |
amercable part number | 37-102*-610cirag |