Amercable CIR Power Cable 4/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-319

Amercable CIR Power Cable 4/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-319

Select gauge from drop-down menu for prices:

Amercable CIR Power Cable 4/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-319
Amercable CIR Power Cable 4/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-319

Conductor: Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.

Insulation: GEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V.

Safer to Handle: CIR® has no sharp metal armor edges that imperil worker’s hands during splicing and installation of connectors

Jacket: A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/ CSA 245 and IEEE 1580.

Application: Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions.

Features:
• Complies with the requirements for TC-ER-HL per UL 2225*
• Exceeds CSA cold bend / cold impact (-40°C / -35°C)
• Gas & vapor tight – impervious to water and air
• Smaller bend radius (up to 40% smaller) than Type MC
• Reduced tray fill (up to 35% less) compared to Type MC
• Considerably more flexible than Type MC
• Reduced installation time and cost compared to Type MC
• Glands for this product cost up to 50% LESS than those for Type MC

CIR®Ratings & Approvals:
• 90°C temperature rating
• UL Listed as Marine Shipboard Cable (E111461)
• UL Listed as Type TC-ER
• UL Listed as TC-ER-HL (cables up to 1” in diameter)
• American Bureau of Shipping (ABS) (99-BT5905-X)
• Flame Retardant – IEEE 1202
• Suitable for use in Class I, Div 2 and Zone 2 environments
• Suitable for Class 1, Div 1 and Zone 1 environments (cables up to 1” in diameter)

technical specification:
conductor size(awg/kcmil) 4/0
conductor size(mm2) 109
number of conductors 3
grounding conductor awg/kcmil 4
nominal diameter(inches) 1.769
weight(lbs/1000 ft.) 3151
90°c nec ampacity 260
75°c nec ampacity 230
dc resistance at 25°c ampacity 0.0585
ac resistance at 90°c, 60hz(ohms/1000 ft.) 0.0753
inductive reactance(ohms/1000 ft.) 0.0261
voltage drop (volts/amp/1000 ft.) 0.131
amercable part number 37-102-319CIRGAG

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.