Amercable Standard VFD 4 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-312
Select gauge from drop-down menu for prices:
- Amercable Standard VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102VFD
- Amercable Standard VFD 14 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-508
- Amercable Standard VFD 12 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-516
- Amercable Standard VFD 10 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-308
- Amercable Standard VFD 8 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-309
- Amercable Standard VFD 6 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-310
- Amercable Standard VFD 4 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-312
- Amercable Standard VFD 2 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-314
- Amercable Standard VFD 1 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-315
- Amercable Standard VFD 1/0 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-316
- Amercable Standard VFD 2/0 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-317
- Amercable Standard VFD 3/0 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-318
- Amercable Standard VFD 4/0 AWG Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-319
- Amercable Standard VFD 262MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-320
- Amercable Standard VFD 313MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-321
- Amercable Standard VFD 373MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-322
- Amercable Standard VFD 444MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-323
- Amercable Standard VFD 535MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-324
- Amercable Standard VFD 646MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-326
- Amercable Standard VFD 777MCM Unarmored Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-327
- Amercable Standard VFD 14 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-508
- Amercable Standard VFD 12 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-516
- Amercable Standard VFD 10 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-308
- Amercable Standard VFD 8 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-309
- Amercable Standard VFD 6 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-310
- Amercable Standard VFD 2 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-314
- Amercable Standard VFD 1 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-315
- Amercable Standard VFD 1/0 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-316
- Amercable Standard VFD 2/0 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-317
- Amercable Standard VFD 3/0 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-318
- Amercable Standard VFD 4/0 AWG Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-319
- Amercable Standard VFD 262MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-320
- Amercable Standard VFD 313MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-321
- Amercable Standard VFD 373MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-322
- Amercable Standard VFD 444MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-323
- Amercable Standard VFD 535MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-324
- Amercable Standard VFD 646MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-326
- Amercable Standard VFD 777MCM Armored & Sheathed(TS) Power Cable Gexol Insulated Three Conductor 2kV Rated 110C 37-102-327
Power Conductors (x3): Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.
Ground Conductors (x3): Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11. Gexol® insulated and sized per UL 1277. Color: Green
Insulation (2kV): Gexol® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. Color: Gray with printed phase I.D. (Black-White-Red)
Shield: Overall tinned copper braid plus aluminum/polyester tape providing 100% coverage.
Jacket: A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL1309/CSA 245 and IEEE 1580.
Armor (Optional): Tinned copper basket weave wire armor per IEEE 1580 and UL 1309/CSA 245.
Sheath (Optional): A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.
Ratings & Approvals:
• 110°C Temperature Rating
• American Bureau of Shipping (ABS)
• Transport Canada
• Det Norske Veritas (DNV)
• Lloyd’s Register of Shipping (LRS)
• NVE: 95/1696, FAL
• UL Listed as Marine Shipboard Cable: (E111461)
• Unarmored Cable is UL Listed as Type TC (E123629)
• United States Coast Guard: November 2, 1987 / 9304
Application: A flexible, braid and foil shielded, 2kV power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications.
Features:
• Specially engineered cable design produces a longer cable life in VFD applications.
• Overall braid plus foil shield is engineered with 100% coverage and a surface transfer impedance <50 milliohms at 10MHz to contain EMI.
• Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive.
• High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable.
• Gexol’s lower dielectric constant (standard XLPEs, EPRs and other Type P insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system.
• 2kV insulation thickness is used to resist the potential 2-3x reflected voltages experienced in 600V VFD applications.
• Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.
• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C.
• Severe cold durability: exceeds CSA cold bend/cold impact (-40°C/-35°C).
• Flame retardant: IEC 332-3 Category A and IEEE 1202.
• Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).
• Optional braid armor of bronze, aluminum or tinned copper.
technical specifications: | |
size awg/kcmil | 4 |
mm2 | 21 |
nominal diameter inches* | 1.262 |
weight lbs./1000 ft. | 1138 |
dc resist. at 25°c ohms/1000 ft. | 0.300 |
ac resist. at 90°c, 60 hz ohms/1000 ft. | 0.399 |
inductive reactance ohms/1000 ft. | 0.031 |
voltage drop at 90°c volts/amp/1000 ft. | 0.584 |
grounding conductor** size (awg) | 12 |
ampacity - 110°c | 99 |
ampacity - 100°c | 92 |
ampacity - 90°c | 83 |
ampacity -75°c | 70 |
amercable part number | 37-102-312tsvfd |