General Cable Armored Thermocouple Single Pair EX 16 Gauge Overall Shield UL Type ITC PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Thermocouple Single Pair Overall Shield UL Type ITC PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Thermocouple Single Pair JX 16 Gauge Overall Shield UL Type ITC PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Thermocouple Single Pair KX 16 Gauge Overall Shield UL Type ITC PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Thermocouple Single Pair TX 16 Gauge Overall Shield UL Type ITC PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Conductor: 16 AWG solid alloy wire per ANSI MC 96.1
Insulation:
• Flame-retardant Polyvinyl Chloride (PVC), rated 105°C per UL Standards 13 and 2250
• Color-coded per ANSI
Pair Assembly: Insulated conductors are cabled together with a left-hand lay
Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors
Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacket removal
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requirements of NEC Article 250
Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250
• ANSI color-coded
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
Applications:
• CCW armored Thermocouple Extension cables provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC or PLTC wiring methods
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C
Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309/CSA C22.2 No. 245 Marine Shipboard Cable
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A
Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant
technical specifications: | |
wire type/size(awg) | ex / 16 |
no. of pairs | 1 |
insulation thickness(mils) | 20 |
insulation thickness(mm) | 0.51 |
inner jacket thickness(mils) | 54 |
inner jacket thickness(mm)
|
1.37 |
nominal core o.d.(inches) | 0.30 |
nominal core o.d.(mm) | 7.6 |
nominal armor o.d.(inches) | 0.47 |
nominal armor o.d.(mm) | 11.9 |
jacket thickness(mils) | 50 |
jacket thickness(mm)
|
1.27 |
nominal overall o.d.(inches) | 0.58 |
nominal overall o.d.(mm) | 14.7 |
crosssectional area¹(sq. in.) | 0.27 |
approximate net weight(lbs/1000 ft) | 160 |
approximate net weight(kg/1000 m)
|
238 |
catalog number | 9025.16010001 |