Description:
• CAT3 (16MHz), 25-Pair, U/UTP-Unshielded, Riser-CMR, Premise Backbone Cable, 24 AWG solid bare copper conductors, S-R PVC insulation, PVC jacket.

Insulation:
• Material: PO - Polyolefin

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.399

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 97 lbs/1000 ft.
• Max. Recommended Pulling Tension: 155 lbs.
• Min. Bend Radius/Minor Axis: 3.300 in.
• Min. Bend/Installation: 3.300 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR-444
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 802.3 10BaseT, 100BaseT4
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: NEMA WC-63 Category 3, UL verified to TIA/EIA-568-B.2, Category 3.

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 61
• Nominal Delay (ns/ft): 1.5
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5

Flame Test:
• UL Flame Test: UL1666 Riser
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24
# pairs 25
stranding solid
no. of conductors 50
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) -