Belden 26514 18 AWG 1 Pair 300V ACIC Multi Conductor Steel Cable
Select gauge from drop-down menu for prices:
- Belden 18 AWG CSA Instrumentation 300V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x26 Cable
- Belden 23533 18 AWG 1 Pair 300V ACIC Multi Conductor Aluminum Cable
- Belden 23511 18 AWG 2 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23530 18 AWG 4 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23528 18 AWG 6 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23531 18 AWG 8 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23524 18 AWG 12 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23519 18 AWG 16 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23542 18 AWG 24 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 23554 18 AWG 36 Pairs 300V ACIC Multi Conductor Aluminum Cable
- Belden 26515 18 AWG 2 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26516 18 AWG 4 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26517 18 AWG 6 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26518 18 AWG 8 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26519 18 AWG 12 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26520 18 AWG 16 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26521 18 AWG 24 Pairs 300V ACIC Multi Conductor Steel Cable
- Belden 26555 18 AWG 36 Pairs 300V ACIC Multi Conductor Steel Cable
Description:
• 18 AWG pairs stranded (7x26) tinned copper conductors, individual Beldfoil plus a polyester isolation tape, PVC insulation, PVC inner jacket, overall Beldfoil shield (100% coverage), drain wires, interlocked armor, PVC outer jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.635
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 7.62
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Y
Armor:
• Armor Type: Interlocked
• Armor Material: Steel
• Diameter over Armor: 0.50
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 383.956 Kg/Km
• Max. Recommended Pulling Tension: 253.547 N
• Min. Bend Radius/Minor Axis: 182.880 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CEC/C(UL) Specification: ACIC
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 22.3108
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 32.81
• Max. Operating Voltage - Other: 300 (CEC ACIC)
Flame Test:
• C(UL) Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# pairs | 1 |
stranding | 7x26 |
no. of conductors | 2 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 15.240 |
belden cable part number - steel | 26514 |