Description:
• 18 AWG stranded (19x30) TC conductors, conductors cabled, plenum, FEP insulation, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, natural Flamarrest® jacket.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1778

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 19x32
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.381

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 60°C
• Bulk Cable Weight: 49.111 Kg/Km
• Max. Recommended Pulling Tension: 507.095 N
• Min. Bend Radius/Minor Axis: 44.450 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.49215
• Nom. Capacitance Conductor to Conductor (pF/m): 98.43
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 206.703
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 20.9984
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 25.9199
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4.3 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 9418

technical specification:
awg 18
# conductors 4
stranding 19x30
no. of conductors 4
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape w/shorting fold
overall cable- nominal dia. (mm) 4.369
belden cable part number 82418