Belden 8437 Cable 22 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Solid TC PVC Jacket Cable

Belden 8437 Cable 22 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Solid TC PVC Jacket Cable

Belden 8437 Cable 22 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Solid TC PVC Jacket Cable

Description:
• Overall braid, 22 AWG solid TC conductors, PVC insulation, twisted pair, polyester tape + TC braid shield (90% coverage), 22 AWG solid TC drain wire, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.381

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: Solid
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.635

Overall Cable:
• Separator Material: Polyester Tape

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2095)
• Bulk Cable Weight: 32.740 Kg/Km
• Max. Recommended Pulling Tension: 213.514 N
• Min. Bend Radius/Minor Axis: 50.800 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2095 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 46
• Nom. Inductance (μH/m): 0.6562
• Nom. Capacitance Conductor to Conductor (pF/m): 157.488
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 278.885
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 53.1522
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 16.0769
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2095)
• Max. Recommended Current: 2.9 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# pairs 1
stranding solid
no. of conductors 2
conductor material tinned copper
outer shield - type braid
outer shield - material tinned copper
overall cable- nominal dia. (mm) 4.775
belden cable part number 8437

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question