Belden 9184 Cable 22 AWG 2 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor TC Solid PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Overall Beldfoil Shield Audio Control and Instrumentation Solid Multi Conductor Paired Cable
- Belden 9302 Cable 22 AWG 2 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9305 Cable 22 AWG 4 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9306 Cable 22 AWG 6 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9309 Cable 22 AWG 9 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9315 Cable 22 AWG 15 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9319 Cable 22 AWG 19 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 9327 Cable 22 AWG 27 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 8751 Cable 22 AWG 51 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable
- Belden 8752 Cable 22 AWG 38 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor TC Solid PVC Jacket Cable
Description:
• 22 AWG solid tinned copper conductors, Datalene® insulation, twisted pairs, Duofoil shield (100% coverage), 22 AWG stranded tinned copper drain wire, PVC jacket.
Insulation:
• Trade Name: Datalene®
• Material: FPE - Foam Polyethylene
• Wall Thickness (mm): 0.889
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.041
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 60°C (UL AWM Style 2668)
• Bulk Cable Weight: 93.757 Kg/Km
• Max. Recommended Pulling Tension: 177.928 N
• Min. Bend Radius/Minor Axis: 101.600 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2668 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/13/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 150
• Nom. Inductance (μH/m): 0.88587
• Nom. Capacitance Conductor to Shield (pF/m): 46.2621
• Nom. Capacitance Conductor to Conductor (pF/m): 28.5447
• Nominal Velocity of Propagation (VP %): 78
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 54.1365
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 26.248
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.6 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
technical specification: | |
awg | 22 |
# pairs | 2 |
stranding | solid |
no. of conductors | 4 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape-aluminum foil |
overall cable- nominal dia. (mm) | 10.160 |
belden cable part number | 9184 |