General Cable EmPowr® 260Miles 500MCM 25 kV Longitudinally Applied Corrugated Tape 1.685 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
Select gauge from drop-down menu for prices:
- General Cable EmPowr® 25 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation
- General Cable EmPowr® 260Miles 250MCM 25 kV Longitudinally Applied Corrugated Tape 1.434 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 250MCM 25 kV Longitudinally Applied Corrugated Tape 1.454 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 350MCM 25 kV Longitudinally Applied Corrugated Tape 1.551 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 350MCM 25 kV Longitudinally Applied Corrugated Tape 1.557 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 500MCM 25 kV Longitudinally Applied Corrugated Tape 1.679 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 750MCM 25 kV Longitudinally Applied Corrugated Tape 1.926 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 750MCM 25 kV Longitudinally Applied Corrugated Tape 1.932 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 1000MCM 25 kV Longitudinally Applied Corrugated Tape 2.075 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
- General Cable EmPowr® 260Miles 1000MCM 25 kV Longitudinally Applied Corrugated Tape 2.081 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.
Product Details
Complete Cable: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.
Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum.
Conductor Shield: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.
Insulation: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).
Insulation Shield: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.
Longitudinally Applied Corrugated Tape: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.
Jacket: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).
Features and Benefits:
• Lead-free environmentally friendly cable
• Even distribution of fault current and better heat dissipation
• Allows expansion/contraction of the cable core
• Improved bending characteristics versus helical copper tape shield
• Triple-extruded for clean interfaces
• Class 10,000 environment utilized for cable core material handling
• Excellent moisture resistance
• High dielectric strength
• Low dielectric loss
• Excellent resistance to water treeing
• Clean-stripping insulation shield
• Sunlight-resistant
Temperature Rating:
• Normal - 90°C
• Emergency* - 130°C
• Short Circuit - 250°C
Applications: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.
Options:
• Copper conductors
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610
• BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core/LACT
• TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core/LACT 3. sealed overlap and blocked LACT/jacket
• Sealed LACT overlap
• True Triple Extrusion
• Low-strip insulation shield
• Red stripes on jacket
• Semi-conducting thermoplastic jacket
• 3 X 1/C triplex or parallel
• Type MV-90 UL 1072
• TRXLPE Class III insulation for 105°/140°C temperature rating
• UL Listed
technical specifications: | |
compressed conductor (al awg or kcmil) | 500 |
compressed conductor (no. of wires) | 37 |
diameter (1) inches (min. insulation) | 1.310 |
diameter (1) inches (max. insulation) | 1.405 |
diameter (1) inches (lact shield - thkn.) | 0.010 |
diameter (1) inches (lact shield - o.d.) | 1.525 |
diameter (1) inches (lldpe jacket) | 1.685 |
nominal jacket thkn. inches(1) | 0.080 |
approx. weight (1) lb/1000 ft (al cond) | 468 |
pprox. weight (1) lb/1000 ft (cu shield)
|
249 |
approx. weight (1) lb/1000 ft (total) | 1382 |
ampacity (2) (direct buried) | 545 |
ampacity (2) (in duct) | 425 |